Deprotonation reactions of multiply protonated ubiquitin ions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The gas‐phase deprotonation reactions of multiply protonated ubiquitin ions have been studied in a Fourier‐transform ion cyclotron resonance mass spectrometer. Electrospray ionization was used to generate ubiquitin ions with attachment of 7–13 protons. Rate constants were measured for the reactions of these protein ions with four amines: n‐propylamine, di‐n‐propylamine, tri‐n‐propylamine, and N,N,N ′, N ′‐tetramethyl‐1,4‐diaminobutane. The gas‐phase basicities of the amines ranged from 210.1 kcal/mol to 232.6 kcal/mol. The rate constants were found to increase as the charge state of the ion increased and as the basicity of the amine increased. Several reactions proceed at near the collision rate and have rate constants in excess of 10 −8 cm 3 molecule −1 s −1 . With the more basic reactants, multiple protons could be stripped sequentially from ubiquitin ions at roughly equivalent rates, suggsting that these protons are attached to sites with similar basicities. In general, deprotonation occurs if the gas‐phase basicity of the amine is within 10 kcal/mol of the intrinsic gas‐phase basicity of the amino acid residue being deprotonated. For [M+ n H] n + , n = 4–6, nonlinear pseudo‐first‐order kinetic behavior indicated the presence of multiple ion structures. Kinetic, structural and thermodynamic aspects of these reactions are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Empirical methods for determination of ionization gauge relative sensitivities for different gases
Bartmess, J. E., & Georgiadis, R. M. (1983) · Vacuum · doi:10.1016/0042-207x(83)90004-0 · Cited by 671
Cited by
Three-Dimensional Ion Mobility/TOFMS Analysis of Electrosprayed Biomolecules
Hoaglund, C. S., Valentine, S. J., Sporleder, C. R., Reilly, J. P., & Clemmer, D. E. (1998) · Analytical Chemistry · doi:10.1021/ac980059c · Cited by 345
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Ion/Ion Proton Transfer Reactions for Protein Mixture Analysis
Stephenson, J. L., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac9605657 · Cited by 145
Metadata
- Authors
- Cassady, C. J., Wronka, J., Kruppa, G. H., Laukien, F. H., & Hettich, R.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1994-05
- Volume
- 8
- Issue
- 5
- Pages
- 394-400
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2157090832
- Cited by
- 80
- References
- 1
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deprotonation reactions of multiply protonated ubiquitin ions. https://app.cochat.ai/papers/10.1002/rcm.1290080511
- The paper
- Cassady, C. J., Wronka, J., Kruppa, G. H., Laukien, F. H., & Hettich, R. (1994). Deprotonation reactions of multiply protonated ubiquitin ions. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1290080511
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.