Chromatofocusing nonporous reversed‐phase high‐performance liquid chromatography/electrospray ionization time‐of‐flight mass spectrometry of proteins from human breast cancer whole cell lysates: a novel two‐dimensional liquid chromatography/mass spectrometry method
Open accessThe DOI matches its Crossref record.
Abstract
A novel two‐dimensional two‐column liquid chromatography/mass spectrometry (LC/MS) technique is described in this work, where chromatofocusing (CF) has been coupled to nonporous reversed‐phase (NPS‐RP) HPLC to separate proteins from human breast epithelial whole cell lysates. The liquid fractions from NPS‐RP‐HPLC are readily amenable to direct on‐line analysis using electrospray ionization orthogonal acceleration time‐of‐flight mass spectrometry (ESI‐TOFMS). A key advantage of this technique is that proteins can be ‘peeled off’ in the liquid phase from the CF column according to their isoelectric points ( pI ) in the first chromatographic separation dimension. The NPS‐RP‐HPLC column further separates these pI ‐focused fractions based upon protein hydrophobicity as the second chromatographic dimension. The third dimension involves on‐line molecular weight determination using ESI‐TOFMS. As a result, this method has the potential to be fully automated. In addition, a 2‐D protein map of pI versus molecular weight is generated, which is analogous to a 2‐D gel image. Thus, this technique may provide a means to study differential expression of proteins from whole cell lysates. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“variant of IEX which uses a change in pH rather than ionic strength to achieve elution, has been coupled to off-line RPLC for fractionation of intact proteins from breast cancer [17] and Methanosarcina acetivorans [38].”
BackgroundPatrie, S. M., Ferguson, J. T., Robinson, D. E., Whipple, D., Rother, M., Metcalf, W. W., & Kelleher, N. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500219-mcp200 · Cited by 62
“ization of 101 intact proteins from whole cell lysates of Methanosarcina acetivorans (43).”
BackgroundMethodInfluential
Metadata
- Authors
- Chong, B. E., Yan, F., Lubman, D. M., & Miller, F. R.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2001-01-30
- Volume
- 15
- Issue
- 4
- Pages
- 291-296
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2057808920
- Cited by
- 97
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.