Direct combination of immersed single‐drop microextraction with atmospheric pressure matrix‐assisted laser desorption/ionization tandem mass spectrometry for rapid analysis of a hydrophilic drug via hydrogen‐bonding interaction and comparison with liquid‐liquid extraction and liquid‐phase microextraction using a dual gauge microsyringe with a hollow fiber
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study presents the feasibility of direct coupling of the immersed single‐drop microextraction (SDME) technique with atmospheric pressure matrix‐assisted laser desorption/ionization mass spectrometry (AP‐MALDI‐MS) for the rapid analysis of a hydrophilic drug (dopamine) from aqueous solution and human urine in an ion trap tandem mass spectrometer through hydrogen‐bonding interaction of dopamine with the extraction solvent (octanol). The optimum conditions for the SDME experiments coupled to AP‐MALDI/MS were: stirring rate, 240 rpm; extraction time, 5 min; sample pH value, 8; and matrix concentration, 2000 ppm, using α ‐cyano‐4‐hydroxycinnamic acid ( α ‐CHCA) as matrix. The limits of detection (LODs) for the SDME/AP‐MALDI‐MS experiments were 25 and 40 ppm in water and human urine, respectively. In a comparison of this method with the traditional liquid‐liquid extraction (LLE), the SDME method shows better LODs than the LLE (40 ppm) and the same LODs (25 ppm) as the liquid‐phase microextraction using a dual gauge microsyringe with a hollow fiber (LPME/DGM‐HF). However, the SDME method is more convenient than the LPME/DGM‐HF method. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Critical review on recent developments in solventless techniques for extraction of analytes
Nerín, C., Salafranca, J., Aznar, M., & Batlle, R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2437-6 · Cited by 284
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Xiong, J., & Hu, B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.072 · Cited by 228
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Metadata
- Authors
- Wu, H., & Lin, C.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-07-24
- Volume
- 20
- Issue
- 16
- Pages
- 2511-2515
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2053760102
- Cited by
- 36
- References
- 1
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct combination of immersed single‐drop microextraction with atmospheric pressure matrix‐assisted laser desorption/ionization tandem mass spectrometry for rapid analysis of a hydrophilic drug via hydrogen‐bonding interaction and comparison with liquid‐liquid extraction and liquid‐phase microextraction using a dual gauge microsyringe with a hollow fiber. https://app.cochat.ai/papers/10.1002/rcm.2612
- The paper
- Wu, H., & Lin, C. (2006). Direct combination of immersed single‐drop microextraction with atmospheric pressure matrix‐assisted laser desorption/ionization tandem mass spectrometry for rapid analysis of a hydrophilic drug via hydrogen‐bonding interaction and comparison with liquid‐liquid extraction and liquid‐phase microextraction using a dual gauge microsyringe with a hollow fiber. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.