CoChat

δ 13 C analyses of calcium carbonate: comparison between the GasBench and elemental analyzer techniques

Skrzypek, Grzegorz, Paul, Debajyoti · 2006 · Rapid Communications in Mass Spectrometry
Cited by 70

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Measurements of stable carbon isotopic composition ( δ 13 C) of carbonates or carbonate‐rich soils are seldom performed in a continuous‐flow isotope ratio mass spectrometer (IRMS) using an elemental analyzer (EA) as an online sample preparation device. Such analyses are routinely carried out with an external precision better than 0.1‰ using a GasBench II (GB) sample preparation device coupled online with a continuous‐flow IRMS. In this paper, we report and compare δ 13 C analyses (86 total analyses) of calcium carbonates obtained by using both the GB and the EA. Using both techniques, the δ 13 C compositions of two in‐house carbonate standards (MERCK carbonate and NR calcite) and ten selected carbonate‐rich paleosol samples (of variable CaCO 3 content) were analyzed, and data are reported in the VPDB scale calibrated against international standards, NBS 18 and 19. For the in‐house standards analyzed by both techniques, a precision better than 0.08‰ is achieved. The analytical errors (1 σ ) computed from multiple analyses of the δ 13 C of both the MERCK and NR obtained by the above two techniques are nearly identical. In general, the 1 σ (internal error) of paleosol analyses obtained in the GB is better than 0.06‰, whereas that for the analyses in the EA (three repetitive analyses of the same sample) varies in the range 0.05–0.21‰. However, for paleosols having more than 85% CaCO 3 , 1 σ is better than 0.15‰ (similar to the instrument precision), and in this case the δ 13 C VPDB of samples obtained by the GB is similar to that obtained by the EA. Our results suggest that the δ 13 C of pure calcium carbonate samples can also be analyzed using the EA technique. Copyright © 2006 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.2688

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 70

Metadata

Authors
Skrzypek, G., & Paul, D.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2006-08-29
Volume
20
Issue
19
Pages
2915-2920
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2137560088
Cited by
70
References
5
FWCI
1.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: δ 13 C analyses of calcium carbonate: comparison between the GasBench and elemental analyzer techniques. https://app.cochat.ai/papers/10.1002/rcm.2688
The paper
Skrzypek, G., & Paul, D. (2006). δ 13 C analyses of calcium carbonate: comparison between the GasBench and elemental analyzer techniques. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2688

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.