Stable isotopes and the international system of units
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
It is now over 60 years since Nier built the first isotope ratio mass spectrometer. The introduction of continuous‐flow techniques heralded a huge expansion in the use of stable isotopes in biomedical and environmental sciences, yet there is no consensus on the appropriate units, especially in the biomedical field. Most isotope ratio mass spectrometry (IRMS) instruments calculate isotopic abundance in terms of delta notation (δ, ‰, per mil), which is a convention determined by geochemistry, because most of the original IRMS instruments were developed in isotope geochemistry laboratories to measure natural abundance variations. Delta units are not SI units. This paper considers the appropriate units for studies using stable isotopes based on the International System of Units (SI). The SI base unit for concentration is the mol, from which atom fraction and mol fraction are derived. The units of stable isotope abundance, atom % and mol %, are the atom and mol fractions expressed as percentages. Atom % excess and mol % excess are the SI units of enrichment and are to be recommended for use in tracer studies. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craig, H. (1957) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(57)90024-8 · Cited by 4,170
New guidelines for reporting stable hydrogen, carbon, and oxygen isotope-ratio data
Coplen, T. B. (1996) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(96)00263-3 · Cited by 862
Reporting of stable hydrogen, carbon, and oxygen isotopic abundances (Technical Report)
Coplen, T. B. (1994) · Pure and Applied Chemistry · doi:10.1351/pac199466020273 · Cited by 856
McKinney, C. R., McCrea, J. M., Epstein, S., Allen, H. A., & Urey, H. C. (1950) · Review of Scientific Instruments · doi:10.1063/1.1745698 · Cited by 745
Radioactive and Stable Isotope Tracers in Biomedicine
Bramlet, R. (1993) · Clinical Nuclear Medicine · doi:10.1097/00003072-199305000-00027 · Cited by 395
A Mass Spectrometer for Routine Isotope Abundance Measurements
Nier, A. O. (1940) · Review of Scientific Instruments · doi:10.1063/1.1751688 · Cited by 384
Preston, T., & Owens, N. J. P. (1983) · The Analyst · doi:10.1039/an9830800971 · Cited by 244
Self-citationDiscontinuance of SMOW and PDB
Coplen, T. B. (1995) · Nature · doi:10.1038/375285a0 · Cited by 215
Sulphur isotope data consistency improved
Coplen, T. B., & Krouse, H. R. (1998) · Nature · doi:10.1038/32080 · Cited by 150
Table of the isotopic composition of the elements as determined by mass spectrometry
Bièvre, P. D., & Barnes, I. L. (1985) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(85)85065-5 · Cited by 120
Cited by
Morrison, D. J., Mackay, W. G., Edwards, C. A., Preston, T., Dodson, B., & Weaver, L. T. (2006) · British Journal of Nutrition · doi:10.1079/bjn20061853 · Cited by 195
“The enrichment of each isotopomer was determined after 6 h of glucose incubation and the data expressed in units of mole percent excess (MPE; Slater et al. 2001).”
MethodSelf-citationBastida, F., Torres, I. F., Hernández, T., & García, C. (2017) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2017.06.012 · Cited by 129
Use of the international system of units (SI) in isotope ratio mass spectrometry
Milton, M. J. T., & Wielgosz, R. I. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.836 · Cited by 12
Metadata
- Authors
- Slater, C., Preston, T., & Weaver, L. T.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2001-07-04
- Volume
- 15
- Issue
- 15
- Pages
- 1270-1273
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2154066047
- Cited by
- 160
- References
- 17
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.