CoChat

FiD: a software for ab initio structural identification of product ions from tandem mass spectrometric data

Open access
Heinonen, Markus, Rantanen, Ari, Mielikäinen, Taneli, Kokkonen, Juha, Kiuru, Jari, Ketola, Raimo A., Rousu, Juho · 2008 · Rapid Communications in Mass Spectrometry
Cited by 140

The DOI matches its Crossref record.

Abstract

We present FiD (Fragment iDentificator), a software tool for the structural identification of product ions produced with tandem mass spectrometric measurement of low molecular weight organic compounds. Tandem mass spectrometry (MS/MS) has proven to be an indispensable tool in modern, cell‐wide metabolomics and fluxomics studies. In such studies, the structural information of the MS n product ions is usually needed in the downstream analysis of the measurement data. The manual identification of the structures of MS n product ions is, however, a nontrivial task requiring expertise, and calls for computer assistance. Commercial software tools, such as Mass Frontier and ACD/MS Fragmenter, rely on fragmentation rule databases for the identification of MS n product ions. FiD, on the other hand, conducts a combinatorial search over all possible fragmentation paths and outputs a ranked list of alternative structures. This gives the user an advantage in situations where the MS/MS data of compounds with less well‐known fragmentation mechanisms are processed. FiD software implements two fragmentation models, the single‐step model that ignores intermediate fragmentation states and the multi‐step model, which allows for complex fragmentation pathways. The software works for MS/MS data produced both in positive‐ and negative‐ion modes. The software has an easy‐to‐use graphical interface with built‐in visualization capabilities for structures of product ions and fragmentation pathways. In our experiments involving amino acids and sugar‐phosphates, often found, e.g., in the central carbon metabolism of yeasts, FiD software correctly predicted the structures of product ions on average in 85% of the cases. The FiD software is free for academic use and is available for download from www.cs.helsinki.fi/group/sysfys/software/fragid . Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.3701

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Heinonen, M., Rantanen, A., Mielikäinen, T., Kokkonen, J., Kiuru, J., Ketola, R. A., & Rousu, J.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2008-09-04
Volume
22
Issue
19
Pages
3043-3052
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2087490875
Cited by
140
References
0
FWCI
3.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: FiD: a software for ab initio structural identification of product ions from tandem mass spectrometric data. https://app.cochat.ai/papers/10.1002/rcm.3701
The paper
Heinonen, M., Rantanen, A., Mielikäinen, T., Kokkonen, J., Kiuru, J., Ketola, R. A., & Rousu, J. (2008). FiD: a software for ab initio structural identification of product ions from tandem mass spectrometric data. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.3701

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.