Enrichment of low molecular weight serum proteins using acetonitrile precipitation for mass spectrometry based proteomic analysis
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A rapid acetonitrile (ACN)‐based extraction method has been developed that reproducibly depletes high abundance and high molecular weight proteins from serum prior to mass spectrometric analysis. A nanoflow liquid chromatography/tandem mass spectrometry (nano‐LC/MS/MS) multiple reaction monitoring (MRM) method for 57 high to medium abundance serum proteins was used to characterise the ACN‐depleted fraction after tryptic digestion. Of the 57 targeted proteins 29 were detected and albumin, the most abundant protein in serum and plasma, was identified as the 20th most abundant protein in the extract. The combination of ACN depletion and one‐dimensional nano‐LC/MS/MS enabled the detection of the low abundance serum protein, insulin‐like growth factor‐I (IGF‐I), which has a serum concentration in the region of 100 ng/mL. One‐dimensional sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS‐PAGE) analysis of the depleted serum showed no bands corresponding to proteins of molecular mass over 75 kDa after extraction, demonstrating the efficiency of the method for the depletion of high molecular weight proteins. Total protein analysis of the ACN extracts showed that approximately 99.6% of all protein is removed from the serum. The ACN‐depletion strategy offers a viable alternative to the immunochemistry‐based protein‐depletion techniques commonly used for removing high abundance proteins from serum prior to MS‐based proteomic analyses. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Kay, R. G., Gregory, B., Grace, P. B., & Pleasance, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3130 · Cited by 119
Self-citation
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Neubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109
Robinson, M. M., Dasari, S., Karakelides, H., Bergen, H. R., & Nair, K. S. (2016) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00175.2016 · Cited by 22
Metadata
- Authors
- Kay, R., Barton, C., Ratcliffe, L., Matharoo‐Ball, B., Brown, P., Roberts, J., Teale, P., & Creaser, C.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2008-09-22
- Volume
- 22
- Issue
- 20
- Pages
- 3255-3260
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2017415179
- Cited by
- 169
- References
- 3
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.