The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improvement of in‐gel digestion protocol for peptide mass fingerprinting by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry
Abstract
High‐sensitivity, high‐throughput analysis of proteins for proteomics studies is usually performed by polyacrylamide gel electrophoresis in combination with mass spectrometry. However, the quality of the data obtained depends on the in‐gel digestion procedure employed. This work describes an improvement in the in‐gel digestion efficiency for matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) analysis. A dramatic improvement in the coverage of tryptic peptides was observed when n‐octyl glucoside was added to the buffer. Whole cell extracted proteins from S. cerevisiae were separated by two‐dimensional gel electrophoresis and stained with silver. Protein spots were identified using our improved in‐gel digestion method and MALDI‐TOFMS. In addition, the mass spectra obtained by using the matrix α‐cyano‐4‐hydroxycinnamic acid (CHCA) were compared with those obtained using 2,5‐dihydroxybenzoic acid (DHB). The DHB matrix usually gave more peaks, which led to higher sequence coverage and, consequently, to higher confidence in protein identification. This improved in‐gel digestion protocol is simple and useful for protein identification by MALDI‐TOFMS. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Erde, J., Loo, R. R. O., & Loo, J. A. (2014) · Journal of Proteome Research · doi:10.1021/pr4010019 · Cited by 331
Gao, J., Li, Y., Wan, Y., Hu, T., Liu, L., Yang, S., Gong, Z., Zeng, Q., Wei, Y., Yang, W., et al. (2019) · Frontiers in Microbiology · doi:10.3389/fmicb.2019.00477 · Cited by 296
Drug Bioactivation Covalent Binding to Target Proteins and Toxicity Relevance
Zhou, S., Chan, E., Duan, W., Huang, M., & Chen, Y.-Z. (2005) · Drug Metabolism Reviews · doi:10.1081/dmr-200028812 · Cited by 274
Phenotypic characterization of OmpX, an Ail homologue of Yersinia pestis KIM
Kolodziejek, A. M., Sinclair, D. J., Seo, K. S., Schnider, D. R., Deobald, C. F., Rohde, H. N., Viall, A. K., Minnich, S. S., Hovde, C. J., Minnich, S. A., et al. (2007) · Microbiology · doi:10.1099/mic.0.2006/005694-0 · Cited by 107
Mass Spectrometry Compatible Surfactant for Optimized In-Gel Protein Digestion
Saveliev, S. V., Woodroofe, C. C., Sabat, G., Adams, C. M., Klaubert, D., Wood, K., & Urh, M. (2013) · Analytical Chemistry · doi:10.1021/ac302423t · Cited by 62
Metadata
- Authors
- Katayama, H., Nagasu, T., & Oda, Y.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2001-07-16
- Volume
- 15
- Issue
- 16
- Pages
- 1416-1421
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2172131613
- Cited by
- 240
- References
- 1
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.