Abstract

Matrix preparation techniques such as air spraying or vapor deposition were investigated with respect to lateral migration, integration of analyte into matrix crystals and achievable lateral resolution for the purpose of high‐resolution biological imaging. The accessible mass range was found to be beyond 5000 u with sufficient analytical sensitivity. Gas‐assisted spraying methods (using oxygen‐free gases) provide a good compromise between crystal integration of analyte and analyte migration within the sample. Controlling preparational parameters with this method, however, is difficult. Separation of the preparation procedure into two steps, instead, leads to an improved control of migration and incorporation. The first step is a dry vapor deposition of matrix onto the investigated sample. In a second step, incorporation of analyte into the matrix crystal is enhanced by a controlled recrystallization of matrix in a saturated water atmosphere. With this latter method an effective analytical resolution of 2 µm in the x and y direction was achieved for scanning microprobe matrix‐assisted laser desorption/ionization imaging mass spectrometry (SMALDI‐MS). Cultured A‐498 cells of human renal carcinoma were successfully investigated by high‐resolution MALDI imaging using the new preparation techniques. Copyright © 2010 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.4401

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Bouschen, W., Schulz, O., Eikel, D., & Spengler, B.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2010-01-04
Volume
24
Issue
3
Pages
355-364
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2019105733
Cited by
186
References
0
FWCI
8.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Matrix vapor deposition/recrystallization and dedicated spray preparation for high‐resolution scanning microprobe matrix‐assisted laser desorption/ionization imaging mass spectrometry (SMALDI‐MS) of tissue and single cells. https://app.cochat.ai/papers/10.1002/rcm.4401
The paper
Bouschen, W., Schulz, O., Eikel, D., & Spengler, B. (2010). Matrix vapor deposition/recrystallization and dedicated spray preparation for high‐resolution scanning microprobe matrix‐assisted laser desorption/ionization imaging mass spectrometry (SMALDI‐MS) of tissue and single cells. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.4401

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.