Quantitation of hepcidin in serum using ultra‐high‐pressure liquid chromatography and a linear ion trap mass spectrometer
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Hepcidin is a peptide hormone that functions as a key regulator of mammalian iron metabolism. Biological levels are increased in end‐stage renal disease and during inflammation but suppressed in hemochromatosis. Thus hepcidin levels have diagnostic importance. This study describes the development of an analytical method for the quantitative determination of the concentration of hepcidin in clinical samples. The fragmentation of hepcidin was investigated using triple quadrupole and linear ion trap mass spectrometers. A standard quantity of a stable isotopically labelled hepcidin internal standard was added to serum samples. Extraction was performed by protein precipitation and weak cation‐exchange magnetic nanoparticles. Chromatography was carried out on sub 2 µm particle stationary phase, using ultra‐high‐pressure liquid chromatography and a linear ion trap for quantitation. The lower limit of quantitation was 0.4 nmol/L with less than 20% accuracy and precision. The mean hepcidin concentration in sera for controls was 4.6 ± 2.7 nmol/L, in patients with sickle cell disease, 7.0 ± 8.9 nmol/L; in patients with end‐stage renal disease, 30.5 ± 15.7 nmol/L; and patients with penetrant hereditary hemochromatosis, 1.4 ± 0.8 nmol/L. Copyright © 2010 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nemeth, E., Rivera, S., Gabayan, V., Keller, C., Taudorf, S., Pedersen, B. K., & Ganz, T. (2004) · Journal of Clinical Investigation · doi:10.1172/jci200420945 · Cited by 2,650
Pigeon, C., Ilyin, G., Courselaud, B., Leroyer, P., Turlin, B., Brissot, P., & Loréal, O. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m008923200 · Cited by 1,697
Hepcidin, a putative mediator of anemia of inflammation, is a type II acute-phase protein
Nemeth, E., Valore, E. V., Territo, M., Schiller, G., Lichtenstein, A., & Ganz, T. (2003) · Blood · doi:10.1182/blood-2002-10-3235 · Cited by 1,417
Nicolas, G., Bennoun, M., Devaux, I., Beaumont, C., Grandchamp, B., Kahn, A., & Vaulont, S. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.151179498 · Cited by 1,233
Hepcidin Revisited, Disulfide Connectivity, Dynamics, and Structure
Jordan, J. B., Poppe, L., Haniu, M., Arvedson, T., Syed, R., Li, V., Kohno, H., Kim, H., Schnier, P. D., Harvey, T. S., et al. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.017764 · Cited by 214
Ashby, D. R., Gale, D. P., Busbridge, M., Murphy, K. G., Duncan, N. D., Cairns, T. D., Taube, D. H., Bloom, S. R., Tam, F. W. K., Chapman, R., et al. (2010) · Haematologica · doi:10.3324/haematol.2009.013136 · Cited by 191
Cited by
Hepcidin and iron regulation, 10 years later
Ganz, T. (2011) · Blood · doi:10.1182/blood-2011-01-258467 · Cited by 962
Hepcidin in Human Iron Disorders: Diagnostic Implications
Kroot, J. J., Tjalsma, H., Fleming, R. E., & Swinkels, D. W. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2009.140053 · Cited by 246
“HPLC/UPLC MS/MS (87;88) c-ELISA (13;29;98;99) (Bachem) Q-TOF LC-MS (92)”
Metadata
- Authors
- Bansal, S. S., Abbate, V., Bomford, A., Halket, J. M., Macdougall, I. C., Thein, S. L., & Hider, R. C.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2010-04-07
- Volume
- 24
- Issue
- 9
- Pages
- 1251-1259
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2111553448
- Cited by
- 53
- References
- 6
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.