CoChat

Extraction of CO 2 from air samples for isotopic analysis and limits to ultra high precision δ 18 O determination in CO 2 gas

Werner, Roland A., Rothe, Michael, Brand, Willi A. · 2001 · Rapid Communications in Mass Spectrometry
Cited by 57

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The determination of δ 18 O values in CO 2 at a precision level of ±0.02‰ (δ‐notation) has always been a challenging, if not impossible, analytical task. Here, we demonstrate that beyond the usually assumed major cause of uncertainty – water contamination – there are other, hitherto underestimated sources of contamination and processes which can alter the oxygen isotope composition of CO 2 . Active surfaces in the preparation line with which CO 2 comes into contact, as well as traces of air in the sample, can alter the apparent δ 18 O value both temporarily and permanently. We investigated the effects of different surface materials including electropolished stainless steel, Duran® glass, gold and quartz, the latter both untreated and silanized. CO 2 frozen with liquid nitrogen showed a transient alteration of the 18 O/ 16 O ratio on all surfaces tested. The time to recover from the alteration as well as the size of the alteration varied with surface type. Quartz that had been ultrasonically cleaned for several hours with high purity water (0.05 µS) exhibited the smallest effect on the measured oxygen isotopic composition of CO 2 before and after freezing. However, quartz proved to be mechanically unstable with time when subjected to repeated large temperature changes during operation. After several days of operation the gas released from the freezing step contained progressively increasing trace amounts of O 2 probably originating from inclusions within the quartz, which precludes the use of quartz for cryogenically trapping CO 2 . Stainless steel or gold proved to be suitable materials after proper pre‐treatment. To ensure a high trapping efficiency of CO 2 from a flow of gas, a cold trap design was chosen comprising a thin wall 1/4″ outer tube and a 1/8″ inner tube, made respectively from electropolished stainless steel and gold. Due to a considerable 18 O specific isotope effect during the release of CO 2 from the cold surface, the thawing time had to be as long as 20 min for high precision δ 18 O measurements. The presence of traces of air in almost all CO 2 gases that we analyzed was another major source of error. Nitrogen and oxygen in the ion source of our mass spectrometer (MAT 252, Finnigan MAT, Bremen, Germany) give rise to the production of NO 2 at the hot tungsten filament. NO 2 + is isobaric with C 16 O 18 O + ( m/z 46) and interferes with the δ 18 O measurement. Trace amounts of air are present in CO 2 extracted cryogenically from air at −196 °C. This air, trapped at the cold surface, cannot be pumped away quantitatively. The amount of air present depends on the surface structure and, hence, the alteration of the measured δ 18 O value varies with the surface conditions. For automated high precision measurement of the isotopic composition of CO 2 of air samples stored in glass flasks an extraction interface (‘BGC‐AirTrap’) was developed which allows 18 analyses (including standards) per day to be made. For our reference CO 2 ‐in‐air, stored in high pressure cylinders, the long term (>9 months) single sample precision was 0.012‰ for δ 13 C and 0.019‰ for δ 18 O. Copyright © 2001 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.487

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Werner, R. A., Rothe, M., & Brand, W. A.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2001-10-23
Volume
15
Issue
22
Pages
2152-2167
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2151897202
Cited by
57
References
1
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.