Comparison between a high‐resolution single‐stage Orbitrap and a triple quadrupole mass spectrometer for quantitative analyses of drugs
The DOI matches its Crossref record.
Abstract
The capabilities of a high‐resolution (HR), accurate mass spectrometer (Exactive‐MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50 000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive‐MS was compared with that of a triple quadrupole mass spectrometer (TQ‐MS), TSQ Quantum Discovery or Quantum Ultra , operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole‐ N ‐oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR‐MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR‐MS offers several benefits over TQ‐MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR‐MS delivers comparable results to TQ‐MS in routine quantitative drug analyses. Considering the advantages of HR‐MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
Vorrink, S. U., Ullah, S., Schmidt, S., Nandania, J., Velagapudi, V., Beck, O., Ingelman‐Sundberg, M., & Lauschke, V. M. (2017) · The FASEB Journal · doi:10.1096/fj.201601375r · Cited by 172
“For a more untargeted approach, highresolutionmass spectrometry (HR-MS) canbeused,which can provide both precise quantification and untargeted data collection for metabolomic evaluation (27).”
BackgroundMelnik, A. V., da Silva, R. R., Hyde, E. R., Aksenov, A. A., Vargas, F., Bouslimani, A., Protsyuk, I., Jarmusch, A. K., Tripathi, A., Alexandrov, T., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01381 · Cited by 87
Gallego, B., Carrión, M. E., Latorre, G., García-Martínez, M. M., Hurtado de Mendoza, J., Zalacain, A., & Carmona, M. (2022) · Industrial Crops and Products · doi:10.1016/j.indcrop.2022.115463 · Cited by 11
Metadata
- Authors
- Henry, H., Sobhi, H. R., Scheibner, O., Bromirski, M., Nimkar, S. B., & Rochat, B.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2012-01-31
- Volume
- 26
- Issue
- 5
- Pages
- 499-509
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2121171062
- Cited by
- 133
- References
- 0
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison between a high‐resolution single‐stage Orbitrap and a triple quadrupole mass spectrometer for quantitative analyses of drugs. https://app.cochat.ai/papers/10.1002/rcm.6121
- The paper
- Henry, H., Sobhi, H. R., Scheibner, O., Bromirski, M., Nimkar, S. B., & Rochat, B. (2012). Comparison between a high‐resolution single‐stage Orbitrap and a triple quadrupole mass spectrometer for quantitative analyses of drugs. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.6121
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.