Ultra-performance liquid chromatography/multiple reaction monitoring mass spectrometry quantification of trastuzumab in human serum by selective monitoring of a specific peptide marker from the antibody complementarity-determining regions
Abstract
Rationale Because of the large molecular weight, the structural complexity and the similarity with endogenous immunoglobulins present in high concentrations, in vivo quantitative studies with therapeutic monoclonal antibodies are particularly challenging. In this work, an UPLC/MRM MS-based methodology is described for the quantification of trastuzumab in human serum by monitoring a novel specific peptide marker located within its heavy chain Complementarity-Determining Region (CDR). Methods For maximum sensitivity and selectivity, specific transitions of this diagnostic proteotypic peptide were optimized and monitored at m/z 364.1 → 437.3 (quantitation ion) and m/z 364.1 → 358.0 (confirmation ion). As a proof-of-concept, the methodology was applied to the determination of trastuzumab in human serum over a clinically relevant range from 0.02 to 200 μg/mL. The methodology has been evaluated in terms of specificity, linearity, accuracy, precision, detection and quantitation limits. Results An excellent linear response has been obtained in the range from 0.036 to 3.6 fmol/μL for the standard peptide and from 0.03 to 285 fmol/μL for the trastuzumab in human serum with typical R 2 values of 0.99. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 fmol/μL and 0.05 fmol/μL, respectively, with mean bias and RSD values of 18% and 1%, respectively, for quality control samples. Conclusions The strategy used to set up the UPLC/MRM MS methodology based on monitoring s…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Expression of an scFv against HER2 derived from Trastuzumab in SHuffle at 30 °C resulted in enhanced solubility and higher expression level compared to its expression in BL21(DE3) at 37 °C.
“Recently, it has been reported that the expression of an scFv against HER2 derived from Trastuzumab (drug bank number DB00072) in SHuffle at 30 °C resulted in enhanced solubility and a higher expression level of the molecule as compared to its expression in BL21 (DE3) at 37 °C [109,110,111,112].”
From Evolution of Escherichia coli Expression System in Producing Antibody Recombinant Fragments (2020) · cites this paper as [112]
The final production yield of anti-HER2 scFv was 147 mg/L under optimal expression conditions (24 h after induction with 0.05 mM IPTG at 30 °C, LB medium, SHuffle strain).
“The final production yield of the anti-HER2 scFv was 147 mg/L, under optimal expression conditions (24 h after induction with 0.05 mM IPTG at 30 °C, LB medium, SHuffle strain).”
From Evolution of Escherichia coli Expression System in Producing Antibody Recombinant Fragments (2020) · cites this paper as [112]
Cited by
Sorted by citations
Evolution of Escherichia coli Expression System in Producing Antibody Recombinant Fragments
Sandomenico, A., Sivaccumar, J. P., & Ruvo, M. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21176324 · Cited by 134 · see citing works
Self-citation
- Authors
- Russo, R., Rega, C., Caporale, A., Tonon, G., Scaramuzza, S., Selis, F., Ruvo, M., & Chambery, A.
- Affiliations
- University of Campania "Luigi Vanvitelli" (IT)
- Institute of Biostructure and Bioimaging (IT)
- MultiMedica (IT)
- Corresponding author
- Chambery, A.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2017-06-18
- Volume
- 31
- Issue
- 14
- Pages
- 1184-1192
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2613878898
- Cited by
- 18
- References
- 0
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 1 · 2021: 1 · 2020: 5 · 2019: 3 · 2018: 3
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Rapid Communications in Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi della Campania "Luigi Vanvitelli" (submittedVersion)
- Topics
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Monoclonal and Polyclonal Antibodies Research
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- trastuzumab, therapeutic monoclonal antibodies, human serum, hypervariable region, proteotypic peptides, antibody quantification, humanized monoclonal antibody, drug monitoring
- MeSH terms
- Trastuzumab, Chromatography, High Pressure Liquid, Humans, Peptide Fragments, Mass Spectrometry, Biomarkers, Linear Models, Drug Monitoring, Complementarity Determining Regions, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review