CoChat

Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual‐inlet cross contamination

Verkouteren, R. Michael, Assonov, Sergey, Klinedinst, Donna B., Brand, Willi A. · 2003 · Rapid Communications in Mass Spectrometry
Cited by 28

The DOI matches its Crossref record.

Abstract

We report high‐precision isotopic carbon dioxide measurements, made before and after ion source modification to gas isotope ratio mass spectrometry (IRMS) instruments. Measurement protocols were designed to explore the effects of ion source material substitution, source conductance, inlet pressure, electron emission, acceleration potential, and inlet changeover equilibration time. After modification of the IRMS instruments at the National Institute of Standards and Technology (NIST) and the Max‐Planck‐Institute for Chemistry (MPI‐Mainz), immediate changes were observed. At NIST, measurements were no longer sensitive to inlet equilibration times greater than 15 s, and different settings of ion source conductance resulted in δ 13 C shifts of about 0.04‰ per 10‰ measurement difference between sample and reference, a five‐fold improvement. No significant changes in machine performance were observed after a month of use. After a year, performance had degraded slightly, but was controlled by ion source cleaning and the use of low‐energy ion acceleration to minimize sputtering. At MPI‐Mainz, results were very similar. We report cross‐contamination coefficients measured since 1996, and discuss the role of adsorption, ion implantation, and sputtering on cross contamination in mass spectrometry systems. We recommend that users of high‐precision IRMS instruments test for and minimize the effects described. Published in 2003 by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.906

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 28

Metadata

Authors
Verkouteren, R. M., Assonov, S., Klinedinst, D. B., & Brand, W. A.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2003-03-06
Volume
17
Issue
8
Pages
777-782
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2069309896
Cited by
28
References
0
FWCI
1.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual‐inlet cross contamination. https://app.cochat.ai/papers/10.1002/rcm.906
The paper
Verkouteren, R. M., Assonov, S., Klinedinst, D. B., & Brand, W. A. (2003). Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual‐inlet cross contamination. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.906

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.