CoChat

Trauma Pod: a semi‐automated telerobotic surgical system

Open access
Garcia, Pablo, Rosen, Jacob, Kapoor, Chetan, Noakes, Mark, Elbert, Greg, Treat, Michael, Ganous, Tim, Hanson, Matt, Manak, Joe, Hasser, Chris, Rohler, David, Satava, Richard · 2009 · The International Journal of Medical Robotics and Computer Assisted Surgery
Cited by 102

The DOI matches its Crossref record.

Abstract

Background: The Trauma Pod (TP) vision is to develop a rapidly deployable robotic system to perform critical acute stabilization and/or surgical procedures, autonomously or in a teleoperative mode, on wounded soldiers in the battlefield who might otherwise die before treatment in a combat hospital could be provided. Methods: In the first phase of a project pursuing this vision, a robotic TP system was developed and its capability demonstrated by performing selected surgical procedures on a patient phantom. Results: The system demonstrates the feasibility of performing acute stabilization procedures with the patient being the only human in the surgical cell. The teleoperated surgical robot is supported by autonomous robotic arms and subsystems that carry out scrub‐nurse and circulating‐nurse functions. Tool change and supply delivery are performed automatically and at least as fast as performed manually by nurses. Tracking and counting of the supplies is performed automatically. The TP system also includes a tomographic X‐ray facility for patient diagnosis and two‐dimensional (2D) fluoroscopic data to support interventions. The vast amount of clinical protocols generated in the TP system are recorded automatically. Conclusions: Automation and teleoperation capabilities form the basis for a more comprehensive acute diagnostic and management platform that will provide life‐saving care in environments where surgical personnel are not present. Copyright © 2009 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcs.238

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 102

Metadata

Authors
Garcia, P., Rosen, J., Kapoor, C., Noakes, M., Elbert, G., Treat, M., Ganous, T., Hanson, M., Manak, J., Hasser, C., Rohler, D., & Satava, R.
Venue
The International Journal of Medical Robotics and Computer Assisted Surgery
Publisher
Wiley
Published
2009-02-16
Volume
5
Issue
2
Pages
136-146
ISSN
  • 1478-5951 (ISSN-L)
  • 1478-596X
OpenAlex
W1975179008
Cited by
102
References
0
FWCI
12.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trauma Pod: a semi‐automated telerobotic surgical system. https://app.cochat.ai/papers/10.1002/rcs.238
The paper
Garcia, P., Rosen, J., Kapoor, C., Noakes, M., Elbert, G., Treat, M., Ganous, T., Hanson, M., Manak, J., Hasser, C., Rohler, D., & Satava, R. (2009). Trauma Pod: a semi‐automated telerobotic surgical system. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.238

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.