CoChat

In Situ treatment of PFAS‐impacted groundwater using colloidal activated Carbon

McGregor, Rick · 2018 · Remediation Journal
Cited by 93

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Poly‐ and perfluoroalkyl substances (PFASs) have been identified by many regulatory agencies as contaminants of concern within the environment. In recent years, regulatory authorities have established a number of health‐based regulatory and evaluation criteria with groundwater PFAS concentrations typically being less than 50 nanograms per liter (ng/L). Subsurface studies suggest that PFAS compounds are recalcitrant and widespread in the environment. Traditionally, impacted groundwater is extracted and treated on the surface using media such as activated carbon and exchange resins. These treatment technologies are generally expensive, inefficient, and can take decades to reach treatment objectives. The application of in situ remedial technologies is common for a wide variety of contaminants of concern such as petroleum hydrocarbons and volatile organic compounds; however, for PFASs, the technology is currently emerging. This study involved the application of colloidal activated carbon at a site in Canada where the PFASs perfluorooctanoate (PFOA) and perfluorooctane sulfonic acid (PFOS) were detected in groundwater at concentrations up to 3,260 ng/L and 1,450 ng/L, respectively. The shallow silty‐sand aquifer was anaerobic with an average linear groundwater velocity of approximately 2.6 meters per day. The colloidal activated carbon was applied using direct‐push technology and PFOA and PFOS concentrations below 30 ng/L were subsequently measured in groundwater samples over an 18‐month period. With the exception of perfluoroundecanoic acid, which was detected at 20 ng/L and perfluorooctanesulfonate which was detected at 40 ng/L after 18 months, all PFASs were below their respective method detection limits in all postinjection samples. Colloidal activated carbon was successfully distributed within the target zone of the impacted aquifer with the activated carbon being measured in cores up to 5 meters from the injection point. This case study suggests that colloidal activated carbon can be successfully applied to address low to moderate concentrations of PFASs within similar shallow anaerobic aquifers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rem.21558

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
McGregor, R.
Venue
Remediation Journal
Publisher
Wiley
Published
2018-06
Volume
28
Issue
3
Pages
33-41
ISSN
  • 1051-5658 (ISSN-L)
  • 1520-6831
OpenAlex
W2805133793
Cited by
93
References
5
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.