CoChat
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Error rates in dental microwear quantification using scanning electron microscopy

Grine, F. E., Ungar, P. S., Teaford, M. F. · 2002 · Scanning

Abstract

There is a degree of correlation between dietary habits and dental microwear in extant primates, and this has enabled inferences to be made about prehistoric diets. Several techniques have been used to quantify microwear, but the comparability of results derived from each has not been demonstrated. Moreover, neither intra‐ nor interobserver error rates in microwear quantification have been documented to date. We here assess intra‐ and interobserver error using Microware 4.0, and evaluate intertechnique comparability using the three methods that have been most widely employed in the field. This study documents an overall intraobserver error rate of about 7%, and an overall interobserver error rate of some 9%. Both intra‐and interobserver error appears to be influenced substantially by the nature of the micrograph being measured. In no instance did the results obtained by different observers using Microware 4.0 differ significantly, and there was a reasonable degree of interobserver consistency in the rank ordering of micrographs in relation to any given parameter. The results obtained through the use of different quantitative techniques differed significantly, with an overall intertechnique error rate of approximately 19%. Several variables, including differences in magnification factor, scanning electron microscope kV settings, and specimendetector relationships undoubtedly contribute to the differences among the three methods, but we were not able to assess their relative importance. Microwear quantification permits distinctions between broad dietary categories, but the margin of intra‐ and interobserver error should be taken into account when defining pattern differences between populations (or species) or when documenting seaseasonally mitigated differences within a taxon. In view of the error introduced by the use of different methods, we suggest that a consistent technique, such as offered by the Microware software package, be adopted by current researchers to establish a common microwear database.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/sca.4950240307

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
Grine, F. E., Ungar, P. S., & Teaford, M. F.
Venue
Scanning
Publisher
Wiley
Published
2002-05
Volume
24
Issue
3
Pages
144-153
ISSN
  • 0161-0457 (ISSN-L)
  • 1932-8745
OpenAlex
W3083589381
Cited by
182
References
1
FWCI
46.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.