An adaptive dose-finding design incorporating both toxicity and efficacy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Novel therapies are challenging the standards of drug development. Agents with specific biologic targets and limited toxicity require novel designs to determine doses to be taken forward into larger studies. In this paper, we describe an approach that incorporates both toxicity and efficacy data into the estimation of the biologically optimal dose of an agent in a phase I trial. The approach is based on the flexible continuation-ratio model, and uses straightforward optimal dose selection criteria. Dose selection is based on all patients treated up until that time point, using a continual reassessment method approach. Dose-outcome curves considered include monotonically increasing, monotonically decreasing, and unimodal curves. Our simulation studies demonstrate that the proposed design, which we call TriCRM, has favourable operating characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCullagh, P., & Nelder, J. A. (1989) · doi:10.1007/978-1-4899-3242-6 · Cited by 16,836
Agresti, A. (2002) · Wiley Series in Probability and Statistics · doi:10.1002/0471249688 · Cited by 6,746
Cunningham, D., Humblet, Y., Siena, S., Khayat, D., Bleiberg, H., Santoro, A., Bets, D., Mueser, M., Harstrick, A., Verslype, C., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033025 · Cited by 5,035 · cited 3×
“This design is a modi ed version of TR’s design [1], in that we use the CR model instead of PO model, and adopt di erent decision criteria and stopping rules.”
BackgroundMethodInfluentialRegression Models for Ordinal Data
McCullagh, P. (1980) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1980.tb01109.x · Cited by 4,453
Cited by
Dose Escalation Methods in Phase I Cancer Clinical Trials
Le Tourneau, C., Lee, J. J., & Siu, L. L. (2009) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djp079 · Cited by 867
Adaptive design methods in clinical trials–a review
Chow, S.-C., & Chang, M. (2008) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-3-11 · Cited by 482
“, escalation) design is often used in early phase clinical development to identify the minimum effective dose (MED) and/or the maximum tolerable dose (MTD), which is used to determine the dose level for the next phase clinical trials [31-33].”
Metadata
- Authors
- Zhang, W., Sargent, D. J., & Mandrekar, S.
- Venue
- Statistics in Medicine
- Publisher
- Wiley
- Published
- 2006
- Volume
- 25
- Issue
- 14
- Pages
- 2365-2383
- ISSN
- 0277-6715 (ISSN-L)
- 1097-0258
- OpenAlex
- W2093423617
- Cited by
- 173
- References
- 4
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.