A new calibration test and a reappraisal of the calibration belt for the assessment of prediction models based on dichotomous outcomes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Calibration is one of the main properties that must be accomplished by any predictive model. Overcoming the limitations of many approaches developed so far, a study has recently proposed the calibration belt as a graphical tool to identify ranges of probability where a model based on dichotomous outcomes miscalibrates. In this new approach, the relation between the logits of the probability predicted by a model and of the event rates observed in a sample is represented by a polynomial function, whose coefficients are fitted and its degree is fixed by a series of likelihood‐ratio tests. We propose here a test associated with the calibration belt and show how the algorithm to select the polynomial degree affects the distribution of the test statistic. We calculate its exact distribution and confirm its validity via a numerical simulation. Starting from this distribution, we finally reappraise the procedure to construct the calibration belt and illustrate an application in the medical context. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing the Performance of Prediction Models: A Framework for Traditional and Novel Measures
Steyerberg, E. W., Vickers, A. J., Cook, N. R., Gerds, T., Gonen, M., Obuchowski, N., Pencina, M. J., & Kattan, M. W. (2010) · Epidemiology · doi:10.1097/ede.0b013e3181c30fb2 · Cited by 5,170
Two Further Applications of a Model for Binary Regression
Cox, D. R. (1958) · Biometrika · doi:10.2307/2333203 · Cited by 557
Two further applications of a model for binary regression
COX, D. R. (1958) · Biometrika · doi:10.1093/biomet/45.3-4.562 · Cited by 556 · cited 1×
“It represents the confidence band of the calibration curve, which is a function, based on a generalization of Cox’s calibration curve [6], relating the expected probability e predicted by a model to the frequency p of the event observed in a sample.”
Method
Cited by
Towards better clinical prediction models: seven steps for development and an ABCD for validation
Steyerberg, E. W., & Vergouwe, Y. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu207 · Cited by 1,928
Graphical calibration curves and the integrated calibration index (ICI) for survival models
Austin, P. C., Harrell, F. E., & van Klaveren, D. (2020) · Statistics in Medicine · doi:10.1002/sim.8570 · Cited by 214
Darmon, M., Bourmaud, A., Georges, Q., Soares, M., Jeon, K., Oeyen, S., Rhee, C. K., Gruber, P., Ostermann, M., Hill, Q. A., et al. (2019) · Intensive Care Medicine · doi:10.1007/s00134-019-05653-7 · Cited by 202
Carbone, M., Nardi, A., Flack, S., Carpino, G., Varvaropoulou, N., Gavrila, C., Spicer, A., Badrock, J., Bernuzzi, F., Cardinale, V., et al. (2018) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(18)30163-8 · Cited by 155
Bootstrap confidence intervals for loess-based calibration curves
Austin, P. C., & Steyerberg, E. W. (2014) · Statistics in Medicine · doi:10.1002/sim.6167 · Cited by 19
“In their letter, NFB described the use of a new graphical method, known as the calibration belt, to assess calibration [2, 3].”
Method
Metadata
- Authors
- Nattino, G., Finazzi, S., & Bertolini, G.
- Venue
- Statistics in Medicine
- Publisher
- Wiley
- Published
- 2014-02-04
- Volume
- 33
- Issue
- 14
- Pages
- 2390-2407
- ISSN
- 0277-6715 (ISSN-L)
- 1097-0258
- OpenAlex
- W2168664034
- Cited by
- 135
- References
- 3
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new calibration test and a reappraisal of the calibration belt for the assessment of prediction models based on dichotomous outcomes. https://app.cochat.ai/papers/10.1002/sim.6100
- The paper
- Nattino, G., Finazzi, S., & Bertolini, G. (2014). A new calibration test and a reappraisal of the calibration belt for the assessment of prediction models based on dichotomous outcomes. Statistics in Medicine. https://doi.org/10.1002/sim.6100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.