The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrospray Ion Beam Deposition of Clusters and Biomolecules
Abstract
An ion beam source using electrospray ionization is presented for nondestructive vacuum deposition of mass‐selected large organic molecules and inorganic clusters. Electrospray ionization is used to create an ion beam from a solution containing the nanoparticles or molecules to be deposited. To form and guide the ion beam, radio frequency and electrostatic ion optics are utilized. The kinetic energy distribution of the particles is measured to control the beam formation and the landing process. The particle mass‐to‐charge ratio is analyzed by in situ time‐of‐flight mass spectrometry. To demonstrate the performance of the setup, deposition experiments with gold nanoclusters and bovine serum albumin proteins on graphite surfaces were performed and analyzed by ex situ atomic force microscopy. The small gold clusters are found to form three‐dimensional agglomerations at the surface, preferentially decorating the step edges. In contrast, bovine serum albumin creates two‐dimensional fractal nanostructures on the substrate terraces due to strong intermolecular interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Treier, M., Pignedoli, C. A., Laino, T., Rieger, R., Müllen, K., Passerone, D., & Fasel, R. (2011) · Nature Chemistry · doi:10.1038/nchem.891 · Cited by 454
A review on electrospun polymeric nanofibers: Production parameters and potential applications
Ibrahim, H. M., & Klingner, A. (2020) · Polymer Testing · doi:10.1016/j.polymertesting.2020.106647 · Cited by 402
Imaging proteins at the single-molecule level
Longchamp, J.-N., Rauschenbach, S., Abb, S., Escher, C., Latychevskaia, T., Kern, K., & Fink, H.-W. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1614519114 · Cited by 119
Self-citationMass-Selective Soft-Landing of Protein Assemblies with Controlled Landing Energies
Mikhailov, V. A., Mize, T. H., Benesch, J. L. P., & Robinson, C. V. (2014) · Analytical Chemistry · doi:10.1021/ac5018327 · Cited by 71
Metadata
- Authors
- Rauschenbach, S., Stadler, F. L., Lunedei, E., Malinowski, N., Koltsov, S., Costantini, G., & Kern, K.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2006-03
- Volume
- 2
- Issue
- 4
- Pages
- 540-547
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2057184922
- Cited by
- 167
- References
- 1
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrospray Ion Beam Deposition of Clusters and Biomolecules. https://app.cochat.ai/papers/10.1002/smll.200500479
- The paper
- Rauschenbach, S., Stadler, F. L., Lunedei, E., Malinowski, N., Koltsov, S., Costantini, G., & Kern, K. (2006). Electrospray Ion Beam Deposition of Clusters and Biomolecules. Small. https://doi.org/10.1002/smll.200500479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.