The DOI matches its Crossref record.
Methotrexate‐Immobilized Poly(ethylene glycol) Magnetic Nanoparticles for MR Imaging and Drug Delivery
Abstract
We report the development of a biostable methotrexate‐immobilized iron oxide nanoparticle drug carrier that may potentially be used for real‐time monitoring of drug delivery through magnetic resonance imaging. Methotrexate (MTX) was immobilized on the nanoparticle surface via a poly(ethylene glycol) self‐assembled monolayer (PEG SAM). The cytotoxicity of the nanoparticle–drug conjugate (NP‐PEG‐MTX) to target cells was studied with 9L glioma cells. Cellular uptake experiments showed that the uptake of NP‐PEG‐MTX conjugates by glioma cells was considerably higher than that of control nanoparticles. Magnetic resonance imaging in 9L cells cultured with NP‐PEG‐MTX of various concentrations showed significant contrast enhancement. NP‐PEG‐MTX demonstrated higher cytotoxicity in 9L cells to free MTX in vitro. Leucovorin, an MTX antidote, was used to rescue the cells that had been exposed to NP‐PEG‐MTX or free MTX, and the experiment verified the biocompatibility of NP‐PEG‐MTX conjugates and the MTX on NP‐PEG‐MTX conjugates to be the true source of the cytotoxicity to the target cells. TEM results showed that NP‐PEG‐MTX conjugates were internalized into the 9L cellular cytoplasm and retained its crystal structure therein for up to 144 h, as identified by electron diffraction. This prolonged particle retention may allow physicians to image tumor cells exposed to the NP‐PEG‐MTX conjugate over an extended therapeutic time course.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Reddy, D. H. K., & Lee, S.-M. (2013) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2013.10.002 · Cited by 689
Magnetic nanoparticles for environmental and biomedical applications: a review
Mohammed, L., Gomaa, H. G., Ragab, D., & Zhu, J. (2017) · Particuology · doi:10.1016/j.partic.2016.06.001 · Cited by 682
Metadata
- Authors
- Kohler, N., Sun, C., Fichtenholtz, A., Gunn, J., Fang, C., & Zhang, M.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2006-04-25
- Volume
- 2
- Issue
- 6
- Pages
- 785-792
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2037948892
- Cited by
- 424
- References
- 0
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methotrexate‐Immobilized Poly(ethylene glycol) Magnetic Nanoparticles for MR Imaging and Drug Delivery. https://app.cochat.ai/papers/10.1002/smll.200600009
- The paper
- Kohler, N., Sun, C., Fichtenholtz, A., Gunn, J., Fang, C., & Zhang, M. (2006). Methotrexate‐Immobilized Poly(ethylene glycol) Magnetic Nanoparticles for MR Imaging and Drug Delivery. Small. https://doi.org/10.1002/smll.200600009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.