The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Inertial Manipulation and Transfer of Microparticles Across Laminar Fluid Streams
Abstract
A general strategy for controlling particle movement across streams would enable new capabilities in single‐cell analysis, solid‐phase reaction control, and biophysics research. Transferring cells across streams is difficult to achieve in a well‐controlled manner, since it requires precise control of fluid flow along with external force fields or precisely manufactured mechanical structures. Herein a strategy is introduced for particle transfer based on passive inertial lift forces and shifts in the distribution of these forces for channels with shifting aspect ratios. Uniquely, use of the dominant wall‐effect lift parallel to the particle rotation direction is explored and utilized to achieve controllable cross‐stream motion. In this way, particles are positioned to migrate across laminar streams and enter a new solution without significant disturbance of the interface at rates exceeding 1000 particles per second and sub‐millisecond transfer times. The capabilities of rapid inertial solution exchange (RInSE) for preparation of hematological samples and other cellular assays are demonstrated. Lastly, improvements to inline flow cytometry after RInSE of excess fluorescent dye and focusing for downstream analysis are characterized. The described approach is simply applied to manipulating cells and particles and quickly exposing them to or removing them from a reacting solution, with broader applications in control and analysis of low affinity interactions on cells or particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Duda, D. G., Cohen, K. S., Scadden, D. T., & Jain, R. K. (2007) · Nature Protocols · doi:10.1038/nprot.2007.111 · Cited by 275
Cited by
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationInertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
Metadata
- Authors
- Gossett, D. R., Tse, H. T. K., Dudani, J. S., Goda, K., Woods, T. A., Graves, S. W., & Di Carlo, D.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2012-07-03
- Volume
- 8
- Issue
- 17
- Pages
- 2757-2764
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2119545325
- Cited by
- 163
- References
- 1
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inertial Manipulation and Transfer of Microparticles Across Laminar Fluid Streams. https://app.cochat.ai/papers/10.1002/smll.201200588
- The paper
- Gossett, D. R., Tse, H. T. K., Dudani, J. S., Goda, K., Woods, T. A., Graves, S. W., & Di Carlo, D. (2012). Inertial Manipulation and Transfer of Microparticles Across Laminar Fluid Streams. Small. https://doi.org/10.1002/smll.201200588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.