Applications and potential toxicity of magnetic iron oxide nanoparticles
Abstract
Owing to their unique physical and chemical properties, magnetic iron oxide nanoparticles have become a powerful platform in many diverse aspects of biomedicine, including magnetic resonance imaging, drug and gene delivery, biological sensing, and hyperthermia. However, the biomedical applications of magnetic iron oxide nanoparticles arouse serious concerns about their pharmacokinetics, metabolism, and toxicity. In this review, the updated research on the biomedical applications and potential toxicity of magnetic iron oxide nanoparticles is summarized. Much more effort is required to develop magnetic iron oxide nanoparticles with improved biocompatible surface engineering to achieve minimal toxicity, for various applications in biomedicine.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
SPION toxicity depends on dosing, exposure time, nature of the coating material, hydrodynamic diameter of the particle and SPION-protein interactions.
“In general, SPION toxicity depends on a variety of factors, including - besides dosing and exposure time - also the nature of the coating material, the hydrodynamic diameter of the particle and SPION-protein interactions [119–122].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [121]
In vitro, upon prolonged incubation, surface-coated SPION are typically nontoxic at iron concentrations up to 10 μg/ml, while slight cytotoxicity is seen at 100 μg/ml.
“In vitro, upon prolonged incubation, surface-coated SPION are typically nontoxic at iron concentration up to and 10 μg/ml, while slight cytotoxicity is seen at 100 μg/ml.”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [121]
The citation lists haven’t been fetched yet
References 164 · Cited by 570
- Authors
- Liu, G., Gao, J., Ai, H., & Chen, X.
- Affiliations
- North Sichuan Medical University (CN)
- Xiamen University (CN)
- Sichuan University (CN)
- National Institutes of Health (US)
- Corresponding author
- Liu, Gang
- Chen, Xiaoyuan
- Venue
- Small
- Publisher
- Wiley
- Published
- 2012-09-28
- Volume
- 9
- Issue
- 9-10
- Pages
- 1533-1545
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2064215841
- Cited by
- 570
- References
- 164
- Citations by year
- 2026: 11 · 2025: 32 · 2024: 60 · 2023: 41 · 2022: 53 · 2021: 48 · 2020: 53 · 2019: 41 · 2018: 61 · 2017: 47 · 2016: 45 · 2015: 34 · 2014: 31 · 2013: 13
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Small (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
- Keywords
- magnetic iron oxide nanoparticles, toxicity, pharmacokinetics, biocompatibility, surface engineering, magnetic resonance imaging, drug delivery, gene delivery, biosensing, hyperthermia, biomedical applications
- MeSH terms
- Animals, Ferric Compounds, Humans, Magnetics, Surface Properties, Biomedical Research, Mice, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review