Solvothermal‐Induced Self‐Assembly of Fe2O3/GS Aerogels for High Li‐Storage and Excellent Stability
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A novel solvothermal‐induced self‐assembly approach, using colloid sol as precursor, is developed to construct monolithic 3D metal oxide/GS (graphene sheets) aerogels. During the solvothermal process, graphene oxide (GO) is highly reduced to GS and self‐assembles into 3D macroscopic hydrogels, accompanying with in situ transformation of colloid sol to metal oxides. As a proof of concept, Fe 2 O 3/GS aerogels are synthesized based on Fe(OH)3 sol, in which GS self‐assemble into an interconnected macroporous framework and Fe 2 O 3 nanocrystals (20–50 nm) uniformly deposit on GS. Benefitting from the integration of macroporous structures, large surface area, high electrical conductivity, and good electrode homogeneity, the hybrid electrode manifests a superior rate capability (930, 660 and 520 mAh g−1 at 500, 2000 and 4000 mA g−1, respectively) and excellent prolonged cycling stability at high rates (733 mAh g−1 during 1000 charge/discharge cycles at 2000 mA g−1), demonstrating its great potential for application in high performance lithium ion batteries. The work described here provides a versatile pathway to construct various graphene‐based hybrid aerogels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Wu, Z.-S., Yang, S., Sun, Y., Parvez, K., Feng, X., & Müllen, K. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3030565 · Cited by 2,061
Synthesis of MoS2 nanosheet–graphene nanosheet hybrid materials for stable lithium storage
Zhou, X., Wan, L.-J., & Guo, Y.-G. (2013) · Chemical Communications · doi:10.1039/c3cc38780a · Cited by 304
Cited by
Zhao, Y., Wang, L. P., Sougrati, M. T., Feng, Z., Leconte, Y., Fisher, A., Srinivasan, M., & Xu, Z. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201601424 · Cited by 586
Superstructured Assembly of Nanocarbons: Fullerenes, Nanotubes, and Graphene
Li, Z., Liu, Z., Sun, H., & Gao, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00102 · Cited by 554
Recent advances in three-dimensional graphene based materials for catalysis applications
Qiu, B., Xing, M., & Zhang, J. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00904f · Cited by 502
3D MXene Architectures for Efficient Energy Storage and Conversion
Li, K., Liang, M., Wang, H., Wang, X., Huang, Y., Coelho, J., Pinilla, S., Zhang, Y., Qi, F., Nicolosi, V., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000842 · Cited by 498
Structural design of graphene for use in electrochemical energy storage devices
Chen, K., Song, S., Liu, F., & Xue, D. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00147a · Cited by 446
Metadata
- Authors
- Wang, R., Xu, C., Du, M., Sun, J., Gao, L., Zhang, P., Yao, H., & Lin, C.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2014-02-13
- Volume
- 10
- Issue
- 11
- Pages
- 2260-2269
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2137610140
- Cited by
- 108
- References
- 3
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.