The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Force to Be Reckoned With: A Review of Synthetic Microswimmers Powered by Ultrasound
Abstract
Synthetic microswimmers are a class of artificial nano‐ or microscale particle capable of converting external energy into motion. They are similar to natural microswimmers such as bacteria in behavior and are, therefore, of great interest to the study of active matter. Additionally, microswimmers show promise in applications ranging from bioanalytics and environmental monitoring to particle separation and drug delivery. However, since their sizes are on the nano‐/microscale and their speeds are in the μm s−1 range, they fall into a low Reynolds number regime where viscosity dominates. Therefore, new propulsion schemes are needed for these microswimmers to be able to efficiently move. Furthermore, many of the hotly pursued applications call for innovations in the next phase of development of biocompatible microswimmers. In this review, the latest developments of microswimmers powered by ultrasound are presented. Ultrasound, especially at MHz frequencies, does little harm to biological samples and provides an advantageous and well‐controlled means to efficiently power microswimmers. By critically reviewing the recent progress in this research field, an introduction of how ultrasound propels colloidal particles into autonomous motion is presented, as well as how this propulsion can be used to achieve preliminary but promising applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Purcell, E. M. (1977) · American Journal of Physics · doi:10.1119/1.10903 · Cited by 4,360
Cited by
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Emergent behavior in active colloids
Zöttl, A., & Stark, H. (2016) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/28/25/253001 · Cited by 426
Fuel‐Free Synthetic Micro‐/Nanomachines
Xu, T., Gao, W., Xu, L., Zhang, X., & Wang, S. (2017) · Advanced Materials · doi:10.1002/adma.201603250 · Cited by 417
Acoustically Propelled Nanomotors for Intracellular siRNA Delivery
Esteban-Fernández de Ávila, B., Angell, C., Soto, F., Lopez-Ramirez, M. A., Báez, D. F., Xie, S., Wang, J., & Chen, Y. (2016) · ACS Nano · doi:10.1021/acsnano.6b01415 · Cited by 309
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Metadata
- Authors
- Rao, K. J., Li, F., Meng, L., Zheng, H., Cai, F., & Wang, W.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2015-04-07
- Volume
- 11
- Issue
- 24
- Pages
- 2836-2846
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2155425718
- Cited by
- 227
- References
- 1
- FWCI
- 14.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Force to Be Reckoned With: A Review of Synthetic Microswimmers Powered by Ultrasound. https://app.cochat.ai/papers/10.1002/smll.201403621
- The paper
- Rao, K. J., Li, F., Meng, L., Zheng, H., Cai, F., & Wang, W. (2015). A Force to Be Reckoned With: A Review of Synthetic Microswimmers Powered by Ultrasound. Small. https://doi.org/10.1002/smll.201403621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.