The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improving All‐Inorganic Perovskite Photodetectors by Preferred Orientation and Plasmonic Effect
Abstract
All‐inorganic perovskites have high carrier mobility, long carrier diffusion length, excellent visible light absorption, and well overlapping with localized surface plasmon resonance (LSPR) of noble metal nanocrystals (NCs). The high‐performance photodetectors can be constructed by means of the intrinsic outstanding photoelectric properties, especially plasma coupling. Here, for the first time, inorganic perovskite photodetectors are demonstrated with synergetic effect of preferred‐orientation film and plasmonic with both high performance and solution process virtues, evidenced by 238% plasmonic enhancement factor and 10 6 on/off ratio. The CsPbBr 3 and Au NC inks are assembled into high‐quality films by centrifugal‐casting and spin‐coating, respectively, which lead to the low cost and solution‐processed photodetectors. The remarkable near‐field enhancement effect induced by the coupling between Au LSPR and CsPbBr 3 photogenerated carriers is revealed by finite‐difference time‐domain simulations. The photodetector exhibits a light on/off ratio of more than 10 6 under 532 nm laser illumination of 4.65 mW cm−2. The photocurrent increases from 0.67 to 2.77 μA with centrifugal‐casting. Moreover, the photocurrent rises from 245.6 to 831.1 μA with Au NCs plasma enhancement, leading to an enhancement factor of 238%, which is the most optimal report among the LSPR‐enhanced photodetectors, to the best of our knowledge. The results of this study suggest that all‐inorganic perovskites are promising semiconductors for high‐performance solution‐processed photodetectors, which can be further enhanced by Au plasmonic effect, and hence have huge potentials in optical communication, safety monitoring, and biological sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akkerman, Q. A., D’Innocenzo, V., Accornero, S., Scarpellini, A., Petrozza, A., Prato, M., & Manna, L. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b05602 · Cited by 2,197
Cited by
Low‐Dimensional Metal Halide Perovskite Photodetectors
Wang, H., Li, S., Liu, X., Shi, Z., Fang, X., & He, J. (2021) · Advanced Materials · doi:10.1002/adma.202003309 · Cited by 574
Low dimensional metal halide perovskites and hybrids
Zhou, C., Lin, H., He, Q., Xu, L., Worku, M., Chaaban, M., Lee, S., Shi, X., Du, M.-H., & Ma, B. (2019) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2018.12.001 · Cited by 489
Self-citationA flexible ultrasensitive optoelectronic sensor array for neuromorphic vision systems
Zhu, Q.-B., Li, B., Yang, D.-D., Liu, C., Feng, S., Chen, M.-L., Sun, Y., Tian, Y.-N., Su, X., Wang, X.-M., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22047-w · Cited by 447
Self-citationBi, C., Wang, S., Li, Q., Kershaw, S. V., Tian, J., & Rogach, A. L. (2019) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.9b00290 · Cited by 367
Ultrasensitive and Fast All‐Inorganic Perovskite‐Based Photodetector via Fast Carrier Diffusion
Yang, B., Zhang, F., Chen, J., Yang, S., Xia, X., Pullerits, T., Deng, W., & Han, K. (2017) · Advanced Materials · doi:10.1002/adma.201703758 · Cited by 319
Metadata
- Authors
- Dong, Y., Gu, Y., Zou, Y., Song, J., Xu, L., Li, J., Xue, J., Li, X., & Zeng, H.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2016-08-23
- Volume
- 12
- Issue
- 40
- Pages
- 5622-5632
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2507124625
- Cited by
- 405
- References
- 1
- FWCI
- 23.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving All‐Inorganic Perovskite Photodetectors by Preferred Orientation and Plasmonic Effect. https://app.cochat.ai/papers/10.1002/smll.201602366
- The paper
- Dong, Y., Gu, Y., Zou, Y., Song, J., Xu, L., Li, J., Xue, J., Li, X., & Zeng, H. (2016). Improving All‐Inorganic Perovskite Photodetectors by Preferred Orientation and Plasmonic Effect. Small. https://doi.org/10.1002/smll.201602366
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.