Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

PtTe2‐Based Type‐II Dirac Semimetal and Its van der Waals Heterostructure for Sensitive Room Temperature Terahertz Photodetection

Xu, Huang, Guo, Cheng, Zhang, Jiazhen, Guo, Wanlong, Kuo, Chia‐Nung, Lue, Chin Shan, Hu, Weida, Wang, Lin, Chen, Gang, Politano, Antonio, Chen, Xiaoshuang, Lu, Wei · 2019 · Small

Abstract

Recent years have witnessed rapid progresses made in the photoelectric performance of two‐dimensional materials represented by graphene, black phosphorus, and transition metal dichalcogenides. Despite significant efforts, a photodetection technique capable for longer wavelength, higher working temperature as well as fast responsivity, is still facing huge challenges due to a lack of best among bandgap, dark current, and absorption ability. Exploring topological materials with nontrivial band transport leads to peculiar properties of quantized phenomena such as chiral anomaly, and magnetic‐optical effect, which enables a novel feasibility for an advanced optoelectronic device working at longer wavelength. In this work, the direct generation of photocurrent at low energy terahertz (THz) band at room temperature is implemented in a planar metal–PtTe 2–metal structure. The results show that the THz photodetector based on PtTe 2 with bow‐tie‐type planar contacts possesses a high photoresponsivity (1.6 A W−1 without bias voltage) with a response time less than 20 µs, while the PtTe 2–graphene heterostructure‐based detector can reach responsivity above 1.4 kV W−1 and a response time shorter than 9 µs. Remarkably, it is already exploitable for large area imaging applications. These results suggest that topological semimetals such as PtTe 2 can be ideal materials for implementation in a high‐performing photodetection system at THz band.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/smll.201903362

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 171

Metadata

Authors
Xu, H., Guo, C., Zhang, J., Guo, W., Kuo, C., Lue, C. S., Hu, W., Wang, L., Chen, G., Politano, A., Chen, X., & Lu, W.
Venue
Small
Publisher
Wiley
Published
2019-11-18
Volume
15
Issue
52
Pages
e1903362-e1903362
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W2984062596
Cited by
171
References
2
FWCI
5.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PtTe2‐Based Type‐II Dirac Semimetal and Its van der Waals Heterostructure for Sensitive Room Temperature Terahertz Photodetection. https://app.cochat.ai/papers/10.1002/smll.201903362
The paper
Xu, H., Guo, C., Zhang, J., Guo, W., Kuo, C., Lue, C. S., Hu, W., Wang, L., Chen, G., Politano, A., Chen, X., & Lu, W. (2019). PtTe2‐Based Type‐II Dirac Semimetal and Its van der Waals Heterostructure for Sensitive Room Temperature Terahertz Photodetection. Small. https://doi.org/10.1002/smll.201903362

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.