CoChat

Structural health monitoring of the Tamar suspension bridge: TAMAR BRIDGE

Open access
Koo, K. Y., Brownjohn, J. M. W., List, D. I., Cole, R. · 2013 · Structural Control and Health Monitoring
Cited by 203

The DOI matches its Crossref record.

Abstract

This paper presents experiences and lessons from the structural health monitoring practice on the Tamar Bridge in Plymouth, UK, a 335-m span suspension bridge opened in 1961. After 40 years of operations, the bridge was strengthened and widened in 2001 to meet a European Union Directive to carry heavy goods vehicles up to 40 tonnes by a process in which additional stay cables and cantilever decks were added and the composite deck was replaced with a lightweight orthotropic steel deck. At that time, a structural monitoring system comprising wind, temperature, cable tension and deck level sensors was installed to monitor the bridge behaviour during and after the upgrading. In 2006 and 2009, respectively, a dynamic response monitoring system with real-time modal parameter identification and a robotic total station were added to provide a more complete picture of the bridge behaviour, and in 2006 a one-day ambient vibration survey of the bridge was carried out to characterize low-frequency vibration modes of the suspended structure. Practical aspects of the instrumentation, data processing and data management are discussed, and some key response observations are presented. The bridge is a surprisingly complex structure with a number of inter-linked load–response mechanisms evident, all of which have to be characterized as part of a long-term structural health monitoring exercise. Structural temperature leading to thermal expansion of the deck, main cables and additional stays is a major factor on global deformation, whereas vehicle loading and wind are usually secondary factors. Dynamic response levels and modal parameters show apparently complex relationships among themselves and with the quasi-static load and response. As well as the challenges of fusing and managing data from three distinct but parallel monitoring systems, there is a significant challenge in interpreting the load and response data firstly to diagnose the normal service behaviour and secondly to identify performance anomalies. Copyright © 2012 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.1481

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Koo, K. Y., Brownjohn, J. M. W., List, D. I., & Cole, R.
Venue
Structural Control and Health Monitoring
Published
2012-03-12
Volume
20
Issue
4
Pages
609-625
ISSN
1545-2255 (ISSN-L)
OpenAlex
W1930168503
Cited by
203
References
0
FWCI
17.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.