Structural health monitoring of the Tamar suspension bridge: TAMAR BRIDGE
Open accessThe DOI matches its Crossref record.
Abstract
This paper presents experiences and lessons from the structural health monitoring practice on the Tamar Bridge in Plymouth, UK, a 335-m span suspension bridge opened in 1961. After 40 years of operations, the bridge was strengthened and widened in 2001 to meet a European Union Directive to carry heavy goods vehicles up to 40 tonnes by a process in which additional stay cables and cantilever decks were added and the composite deck was replaced with a lightweight orthotropic steel deck. At that time, a structural monitoring system comprising wind, temperature, cable tension and deck level sensors was installed to monitor the bridge behaviour during and after the upgrading. In 2006 and 2009, respectively, a dynamic response monitoring system with real-time modal parameter identification and a robotic total station were added to provide a more complete picture of the bridge behaviour, and in 2006 a one-day ambient vibration survey of the bridge was carried out to characterize low-frequency vibration modes of the suspended structure. Practical aspects of the instrumentation, data processing and data management are discussed, and some key response observations are presented. The bridge is a surprisingly complex structure with a number of inter-linked load–response mechanisms evident, all of which have to be characterized as part of a long-term structural health monitoring exercise. Structural temperature leading to thermal expansion of the deck, main cables and additional stays is a major factor on global deformation, whereas vehicle loading and wind are usually secondary factors. Dynamic response levels and modal parameters show apparently complex relationships among themselves and with the quasi-static load and response. As well as the challenges of fusing and managing data from three distinct but parallel monitoring systems, there is a significant challenge in interpreting the load and response data firstly to diagnose the normal service behaviour and secondly to identify performance anomalies. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Critical review of data-driven decision-making in bridge operation and maintenance
Wu, C., Wu, P., Wang, J., Jiang, R., Chen, M., & Wang, X. (2022) · Structure and Infrastructure Engineering · doi:10.1080/15732479.2020.1833946 · Cited by 189
“Traffic data Traffic volume FGB sensors (Chen, Wu, & Feng, 2019), weight-in-motion systems (Carrion et al., 2017a; Koo et al., 2013) 10 Vehicle load 19 Vehicle speed 8 STRUCTURE AND INFRASTRUCTURE ENGINEERING 51”
BackgroundAutomated Estimation of Reinforced Precast Concrete Rebar Positions Using Colored Laser Scan Data
Wang, Q., Cheng, J. C. P., & Sohn, H. (2017) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12293 · Cited by 170
“In recent decades, electronic survey devices such as total stations and laser range finders have become available (Suo et al., 2014; Koo et al., 2013).”
BackgroundKostić, B., & Gül, M. (2017) · Journal of Bridge Engineering · doi:10.1061/(asce)be.1943-5592.0001085 · Cited by 74
Sivasuriyan, A., Vijayan, D. S., LeemaRose, A., Revathy, J., Gayathri Monicka, S., Adithya, U. R., & Jebasingh Daniel, J. (2021) · Advances in Materials Science and Engineering · doi:10.1155/2021/2615029 · Cited by 29
“(e bridge was monitored for around four years to measure damage, dynamic behavior, temperature effect, wind force, and displacement [85].”
BackgroundRetracted
Metadata
- Authors
- Koo, K. Y., Brownjohn, J. M. W., List, D. I., & Cole, R.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2012-03-12
- Volume
- 20
- Issue
- 4
- Pages
- 609-625
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W1930168503
- Cited by
- 203
- References
- 0
- FWCI
- 17.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.