The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Recent research and applications of GPS-based monitoring technology for high-rise structures
Abstract
Monitoring the response of structures, especially tall buildings, under severe loading conditions is an important requirement for the validation of their design and construction, as well as being a maintenance concern. This paper presents a review of current research and development activities (since 1995) in the field of high-rise structure health monitoring using the Global Positioning System (GPS). The GPS monitoring technology and its accurate assessment method are firstly briefly described. Then, the progresses on monitoring the displacement of the high-rise structure caused by the ambient effects including wind, thermal variation, and earthquake-induced responses are discussed in details. Following that, the states of the art of augmenting the GPS monitoring technology are reviewed. Finally, existing problems and promising research efforts in the GPS-based health monitoring are given. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structural health monitoring of civil infrastructure
Brownjohn, J. M. W. (2007) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2006.1925 · Cited by 998
Smyth, A. W., & Wu, M. (2006) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2006.03.005 · Cited by 372
Optimal sensor placement for structural health monitoring based on multiple optimization strategies
Yi, T., Li, H., & Gu, M. (2011) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.712 · Cited by 288
Self-citationPsimoulis, P. A., Pytharouli, S. I., Karambalis, D., & Stiros, S. C. (2008) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2008.04.036 · Cited by 135
Psimoulis, P. A., & Stiros, S. C. (2008) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/j.1467-8667.2008.00547.x · Cited by 101
Recent research and applications of GPS based technology for bridge health monitoring
Yi, T., Li, H., & Gu, M. (2010) · Science China Technological Sciences · doi:10.1007/s11431-010-4076-3 · Cited by 96
Self-citationYi, T., Li, H., & Gu, M. (2010) · Science China Technological Sciences · doi:10.1007/s11431-010-0051-2 · Cited by 78
Self-citation
Cited by
Ye, X. W., Su, Y. H., & Han, J. P. (2014) · The Scientific World Journal · doi:10.1155/2014/652329 · Cited by 293
Li, J., Hao, H., & Chen, Z. (2017) · Journal of Aerospace Engineering · doi:10.1061/(asce)as.1943-5525.0000550 · Cited by 44
Metadata
- Authors
- Yi, T.-H., Li, H.-N., & Gu, M.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2012-05-07
- Volume
- 20
- Issue
- 5
- Pages
- 649-670
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W1848411996
- Cited by
- 258
- References
- 7
- FWCI
- 54.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent research and applications of GPS-based monitoring technology for high-rise structures. https://app.cochat.ai/papers/10.1002/stc.1501
- The paper
- Yi, T.-H., Li, H.-N., & Gu, M. (2013). Recent research and applications of GPS-based monitoring technology for high-rise structures. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.1501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.