CoChat

Optimum design for more effective tuned mass damper system and its application to base-isolated buildings: OPTIMUM DESIGN FOR MORE EFFECTIVE TMD

Open access
Xiang, P., Nishitani, A. · 2014 · Structural Control and Health Monitoring
Cited by 117

The DOI matches its Crossref record.

Abstract

Base-isolated structures are vulnerable to long-period ground motions due to resonances. The hybrid control strategy combining traditional tuned mass dampers (TMDs) with base-isolation systems has been proved by some researchers to be effective in preventing the resonant behaviors. However, large space for TMDs is required because of large stroke lengths of TMDs, which may be difficult to realize in practical applications. In this paper, a non-traditional TMD that is directly connected to the ground by a dashpot is adopted to mitigate the resonant behavior of a structure. It is found that the conventional design method of traditional TMDs based on the quasi-fixed points theory cannot provide the global minimum value of the objective function for non-traditional TMD systems. An optimum design method for obtaining a wide suppression bandwidth is proposed. Seismic-induced vibration control for a three degree-of-freedom base-isolated structural system with a non-traditional TMD is studied. The control effect of the optimally designed non-traditional TMD is significantly improved, and the stroke length of the non-traditional TMD is greatly reduced, compared with the traditional TMD during near-field long-period earthquakes. In these regards, non-traditional TMDs may provide a better solution for retrofitting or constructing base-isolated structures. Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.1556

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
Xiang, P., & Nishitani, A.
Venue
Structural Control and Health Monitoring
Published
2013-03-06
Volume
21
Issue
1
Pages
98-114
ISSN
1545-2255 (ISSN-L)
OpenAlex
W1722680130
Cited by
117
References
0
FWCI
5.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimum design for more effective tuned mass damper system and its application to base-isolated buildings: OPTIMUM DESIGN FOR MORE EFFECTIVE TMD. https://app.cochat.ai/papers/10.1002/stc.1556
The paper
Xiang, P., & Nishitani, A. (2014). Optimum design for more effective tuned mass damper system and its application to base-isolated buildings: OPTIMUM DESIGN FOR MORE EFFECTIVE TMD. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.1556

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.