CoChat

Health monitoring sensor placement optimization for Canton Tower using immune monkey algorithm: SENSOR PLACEMENT OPTIMIZATION USING IMMUNE MONKEY ALGORITHM

Open access
Yi, Ting-Hua, Li, Hong-Nan, Zhang, Xu-Dong · 2015 · Structural Control and Health Monitoring
Cited by 78

The DOI matches its Crossref record.

Abstract

Sensor placement is an integral component in the design of an effective and reliable structural health monitoring system for large-scale civil engineering structures. In this paper, a novel hybrid optimization algorithm, that is, immune monkey algorithm (IMA), by combining the monkey algorithm with the immune algorithm, is proposed to solve the optimal sensor placement problem. In the proposed algorithm, the dual-structure coding method is designed and adopted for the representation of design variables and a chaos-based approach is presented to initialize the monkey population. In addition, some improved strategies such as the advanced climb process, immune selection, clonal proliferation, and immune renewal are defined to maintain population diversity and inhibit degeneracy during evolution. The effectiveness and reliability of the proposed IMA is demonstrated by designing the sensor arrays of the Canton Tower, the second highest TV tower in the world. Numerical investigations presented clearly suggest that the proposed hybrid IMA outperforms the original monkey algorithm implementations both in terms of generating optimal solutions as well as faster convergence. The proposed algorithm can easily be extended to other multiple global optimization problems. Copyright © 2014 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.1664

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Yi, T.-H., Li, H.-N., & Zhang, X.-D.
Venue
Structural Control and Health Monitoring
Publisher
Wiley
Published
2014-04-29
Volume
22
Issue
1
Pages
123-138
ISSN
1545-2255 (ISSN-L)
OpenAlex
W1567882266
Cited by
78
References
0
FWCI
16.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.