Optimal sensor placement for health monitoring of high-rise structure using adaptive monkey algorithm: SENSOR PLACEMENT FOR HEALTH MONITORING USING ADAPTIVE MONKEY ALGORITHM
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Optimal sensor placement is a challenging task in the design of an effective structural health monitoring system. In this paper, a novel optimal sensor placement algorithm, called adaptive monkey algorithm (AMA), to cope with the sensor placement problem for target location under constraints of the computing efficiency and convergence stability is proposed. The dual-structure coding method, instead of the traditional coding method, is adopted to code the solution. The adaptive operator is designed and implemented in the AMA, which provides an automatic technique for adjusting the climb process and watch–jump process of the monkey algorithm according to the observed performance while the search is ongoing. Two new somersault processes, i.e., reflection somersault process and mutation somersault process, are incorporated in the AMA to strengthen its global search ability. Numerical experiments involving two high-rise structures have been carried out to evaluate the performance of the proposed AMA algorithm. The results demonstrated that the innovations in the AMA make it outperform the other algorithms in most cases in terms of less iterations and generating more stable optimal solutions. This algorithm can also be easily applied to other discrete optimization problems. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Cited by
The Sensable City: A Survey on the Deployment and Management for Smart City Monitoring
Du, R., Santi, P., Xiao, M., Vasilakos, A. V., & Fischione, C. (2019) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2881008 · Cited by 289
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Deep generative Bayesian optimization for sensor placement in structural health monitoring
Sajedi, S., & Liang, X. (2022) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12799 · Cited by 68
Metadata
- Authors
- Yi, T.-H., Li, H.-N., Song, G., & Zhang, X.-D.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2014-10-15
- Volume
- 22
- Issue
- 4
- Pages
- 667-681
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W1635042630
- Cited by
- 65
- References
- 1
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal sensor placement for health monitoring of high-rise structure using adaptive monkey algorithm: SENSOR PLACEMENT FOR HEALTH MONITORING USING ADAPTIVE MONKEY ALGORITHM. https://app.cochat.ai/papers/10.1002/stc.1708
- The paper
- Yi, T.-H., Li, H.-N., Song, G., & Zhang, X.-D. (2015). Optimal sensor placement for health monitoring of high-rise structure using adaptive monkey algorithm: SENSOR PLACEMENT FOR HEALTH MONITORING USING ADAPTIVE MONKEY ALGORITHM. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.1708
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.