Experimental studies on the effectiveness and robustness of a pounding tuned mass damper for vibration suppression of a submerged cylindrical pipe
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pounding tuned mass damper (PTMD) is a novel type of passive damper. The PTMD utilizes collisions or impacts of a tuned mass with viscoelastic materials to efficiently dissipate the vibration energy of primary structures. The previous studies have verified its effective damping performance on a full-scale subsea jumper and other structures in air. This paper presents the first-ever experimental verification of a submerged PTMD system for vibration control of pipelike structures underwater. To facilitate the experimental studies, a vertical vibration system consisting of 4 springs and a cylindrical steel pipe was designed and set up in a water tank. Furthermore, a numerical method considering the effect of the added mass is described to estimate the natural frequencies of a submerged cylindrical pipe. Therefore, experimental results demonstrate that the PTMD system is effective and efficient to suppress the forced vibrations of the submerged cylindrical pipe at the tuned frequency and is also robust over a range of detuning frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651
Cited by
Vibration analysis and control technologies of hydraulic pipeline system in aircraft: A review
GAO, P., YU, T., ZHANG, Y., WANG, J., & ZHAI, J. (2021) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2020.07.007 · Cited by 286
Vibration control of fluid-conveying pipes: a state-of-the-art review
Ding, H., & Ji, J. C. (2023) · Applied Mathematics and Mechanics · doi:10.1007/s10483-023-3023-9 · Cited by 132
“In studying the vibration control of compressor fluid-conveying pipes, the control methods adopted include semi-active control([134]), pipe configuration optimization([3]), pressure pulsation reduction([161]), active vibration control based on fluid motion([121]), and passive control with the introduction of dynamic v…”
BackgroundMethodUltra-thin Piezoelectric Lattice for Vibration Suppression in Pipe Conveying Fluid
Lyu, X., Chen, F., Ren, Q., Tang, Y., Ding, Q., & Yang, T. (2020) · Acta Mechanica Solida Sinica · doi:10.1007/s10338-020-00174-z · Cited by 52
Kwag, S., Eem, S., Kwak, J., Lee, H., Oh, J., & Koo, G.-H. (2021) · Nuclear Engineering and Technology · doi:10.1016/j.net.2021.02.009 · Cited by 38
Wang, B., Wang, H., He, Z., Liu, D., & Pan, P. (2023) · Engineering Structures · doi:10.1016/j.engstruct.2023.115744 · Cited by 33
Metadata
- Authors
- Jiang, J., Zhang, P., Patil, D., Li, H., & Song, G.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Wiley
- Published
- 2017-05-11
- Volume
- 24
- Issue
- 12
- ISSN
- 1545-2255 (ISSN-L)
- 1545-2263
- OpenAlex
- W2613555631
- Cited by
- 80
- References
- 1
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental studies on the effectiveness and robustness of a pounding tuned mass damper for vibration suppression of a submerged cylindrical pipe. https://app.cochat.ai/papers/10.1002/stc.2027
- The paper
- Jiang, J., Zhang, P., Patil, D., Li, H., & Song, G. (2017). Experimental studies on the effectiveness and robustness of a pounding tuned mass damper for vibration suppression of a submerged cylindrical pipe. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.2027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.