The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Design of structure with inerter system based on stochastic response mitigation ratio
Abstract
An easy-to-use method for a practical design of single-degree-of-freedom (SDOF) structures with inerter systems was developed. The method adopts the stochastic vibration response mitigation ratio as the design index, and expressions of the closed-form stochastic response are used to evaluate the structural response and optimize the design parameters. Three basic types of inerter systems with tuning and damping magnification mechanisms were considered in this study. The closed-form stochastic responses of SDOF structures with inerter systems under white-noise excitations were derived on the basis of the equations of motion. In addition, the response variation patterns due to changes in key parameters of the inerter system were investigated, and the parameter optimization approaches for different inerter systems are proposed on the basis of the response variation patterns. The use of the closed-form stochastic response mitigation ratio as the design index leads to a rational and simple design process, with the tuning or response extremum conditions employed as complementary conditions for determining the key design parameters. Thus, the proposed method involves the solution of a set of nonlinear equations. Fitted empirical design formulae are provided in this paper for quick calculation of the key parameters of the SDOF structure with the inerter system for a given response mitigation ratio and inherent damping ratio. Moreover, design examples are provided to verify the proposed method. The design results show that the proposed method is effective and more convenient than existing methods. Furthermore, the method can be easily extended for considering seismic excitations and design of structures with other complex-form inerter systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of mechanical networks: the inerter
Smith, M. C. (2002) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2002.803532 · Cited by 1,828
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828
Cited by
Inerter-based structural vibration control: A state-of-the-art review
Ma, R., Bi, K., & Hao, H. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.112655 · Cited by 445
Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system
Zhang, R., Zhao, Z., & Dai, K. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2018.11.020 · Cited by 273
Self-citationShen, W., Niyitangamahoro, A., Feng, Z., & Zhu, H. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2019.109470 · Cited by 175
Metadata
- Authors
- Pan, C., & Zhang, R.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Wiley
- Published
- 2018-03-13
- Volume
- 25
- Issue
- 6
- Pages
- e2169
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W2790393596
- Cited by
- 170
- References
- 2
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of structure with inerter system based on stochastic response mitigation ratio. https://app.cochat.ai/papers/10.1002/stc.2169
- The paper
- Pan, C., & Zhang, R. (2018). Design of structure with inerter system based on stochastic response mitigation ratio. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.2169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.