The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Field monitoring and numerical analysis of Tsing Ma Suspension Bridge temperature behavior: TEMPERATURE BEHAVIOR OF TSING MA SUSPENSION BRIDGE
Abstract
It is important to take into account the effect of temperature in assessing the structural condition of bridges. However, very few quantitative studies have examined the temperature behavior of large-scale bridges because of their large size and complicated configuration. This paper, for the first time, investigates the temperature distribution and associated responses of a long-span suspension bridge—the 2132-m-long Tsing Ma Bridge—through a combination of numerical analysis and field monitoring. With appropriate assumptions, fine finite element models of a deck plate, section frame, and bridge tower are constructed to facilitate thermal analysis. With ambient temperature measurements and a solar radiation model, the time-dependent temperature distribution within each of these components is calculated through transient heat transfer analysis. The numerical results are verified by comparing them with field monitoring data on temperature distribution and variation at different times and in different seasons. The temperature data are then input into the structural model of the whole bridge to obtain the displacement and strain responses of various bridge components, with a good level of agreement being achieved between the bridge responses and the monitoring data. This exercise verifies both the accuracy of the analytical method employed and the effectiveness of the monitoring system installed on the bridge. The study shows that integrating numerical analysis with field monitoring data provides for a thorough understanding of the temperature behavior of long-span bridges. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long term vibration monitoring of an RC slab: Temperature and humidity effect
Xia, Y., Hao, H., Zanardo, G., & Deeks, A. (2006) · Engineering Structures · doi:10.1016/j.engstruct.2005.09.001 · Cited by 331
Self-citationMonitoring temperature effect on a long suspension bridge
Xu, Y. L., Chen, B., Ng, C. L., Wong, K. Y., & Chan, W. Y. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.340 · Cited by 219
Self-citationStructural Health Monitoring of Long-Span Suspension Bridges
Xu, Y. L., & Xia, Y. (2011) · doi:10.1201/b13182 · Cited by 203
Self-citation
Cited by
The state of the art in structural health monitoring of cable-stayed bridges
Li, H., & Ou, J. (2016) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-015-0115-x · Cited by 267
Structural health monitoring research under varying temperature condition: a review
Han, Q., Ma, Q., Xu, J., & Liu, M. (2021) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-020-00444-x · Cited by 190
Luo, J., Huang, M., & Lei, Y. (2022) · Buildings · doi:10.3390/buildings12081209 · Cited by 90
Metadata
- Authors
- Xia, Y., Chen, B., Zhou, X.-Q., & Xu, Y.-L.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2012-01-17
- Volume
- 20
- Issue
- 4
- Pages
- 560-575
- ISSN
- 1545-2255 (ISSN-L)
- OpenAlex
- W2141140211
- Cited by
- 242
- References
- 3
- FWCI
- 21.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).