Mitigation of wind‐induced motion of Milad Tower by tuned mass damper
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
With a height of 435 m, Milad Tower, situated in north‐west of Tehran, Iran, would be the fourth highest telecommunication tower of the world. This tower has the largest head structure among its counterparts. Preliminary studies demonstrate that the upper part of the tower has excessive wind‐induced acceleration‐related vibrations beyond human comfort limit during wind events. In this paper, the effectiveness of tuned mass damper (TMD) on the suppression of wind‐induced motion of Milad Tower is examined through mathematical analyses. The tower is modelled as a vertical linear cantilever beam, with 57 degrees of freedom. The fluctuating wind speed is assumed to be a stochastic process which is identified by an appropriate power spectral density function. Random vibration analyses were carried out to determine response statistics. The possible application of TMDs in suppressing wind‐induced motions of the tower was investigated, and a TMD was designed to be installed at the sky dome. The results clearly show that the designed TMD has a considerable influence on the suppression of the structural response of the tower below human comfort limits. The authors believe that Milad Tower can be considered as a benchmark control problem for television and telecommunication towers by the structural control community. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Technology of Semiactive Devices and Applications in Vibration Mitigation
Casciati, F., Magonette, G., & Marazzi, F. (2006) · doi:10.1002/0470022914 · Cited by 149
Cited by
Lu, Z., Chen, X., Zhang, D., & Dai, K. (2017) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2826 · Cited by 186
“TMDs are a traditional passive control device with wide applications, such as in Shanghai Center Tower [7], Taipei 101 [8], Milad Tower [9], and Chiba Port Tower.”
BackgroundStructural control and vibration issues in wind turbines: A review
Xie, F., & Aly, A.-M. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2019.110087 · Cited by 159
Mitigation of wind‐induced response of Shanghai Center Tower by tuned mass damper
Lu, X., & Chen, J. (2011) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.659 · Cited by 83
“…tuned mass damper (TMD) system, the feasibility of which has been verifi ed in practical engineering (Fujino et al., 1996; Soong and Dargush, 1997; Ghorbani-Tanha et al., 2009), will be installed at a height of 565–569 m to suppress the wind-induced motion and to improve the residential comfort…”
BackgroundAly, A. M. (2014) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1068 · Cited by 74
Wang, J., Wierschem, N. E., Wang, B., & Spencer, B. F. (2020) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1692 · Cited by 62
Metadata
- Authors
- Ghorbani‐Tanha, A. K., Noorzad, A., & Rahimian, M.
- Venue
- The Structural Design of Tall and Special Buildings
- Publisher
- Wiley
- Published
- 2008-01-02
- Volume
- 18
- Issue
- 4
- Pages
- 371-385
- ISSN
- 1541-7794 (ISSN-L)
- 1541-7808
- OpenAlex
- W2009448458
- Cited by
- 65
- References
- 2
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mitigation of wind‐induced motion of Milad Tower by tuned mass damper. https://app.cochat.ai/papers/10.1002/tal.421
- The paper
- Ghorbani‐Tanha, A. K., Noorzad, A., & Rahimian, M. (2009). Mitigation of wind‐induced motion of Milad Tower by tuned mass damper. The Structural Design of Tall and Special Buildings. https://doi.org/10.1002/tal.421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.