CoChat

Electrospun fibre diameter, not alignment, affects mesenchymal stem cell differentiation into the tendon/ligament lineage: Ligament differentiation of C3H10T1/2 cells is enhanced on larger fibres

Open access
Cardwell, Robyn D., Dahlgren, Linda A., Goldstein, Aaron S. · 2014 · Journal of Tissue Engineering and Regenerative Medicine
Cited by 143

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Efforts to develop engineered tendons and ligaments have focused on the use of a biomaterial scaffold and a stem cell source. However, the ideal scaffold microenvironment to promote stem cell differentiation and development of organized extracellular matrix is unknown. Through electrospinning, fibre scaffolds can be designed with tailorable architectures to mimic the intended tissue. In this study, the effects of fibre diameter and orientation were examined by electrospinning thin mats, consisting of small (< 1 µm), medium (1-2 µm) or large (> 2 µm) diameter fibres with either random or aligned fibre orientation. C3H10T1/2 model stem cells were cultured on the six different electrospun mats, as well as smooth spin-coated films, and the morphology, growth and expression of tendon/ligament genes were evaluated. The results demonstrated that fibre diameter affects cellular behaviour more significantly than fibre alignment. Initially, cell density was greater on the small fibre diameter mats, but similar cell densities were found on all mats after an additional week in culture. After 2 weeks, gene expression of collagen 1α1 and decorin was increased on all mats compared to films. Expression of the tendon/ligament transcription factor scleraxis was suppressed on all electrospun mats relative to spin-coated films, but expression on the large-diameter fibre mats was consistently greater than on the medium-diameter fibre mats. These results suggest that larger-diameter fibres (e.g. > 2 µm) may be more suitable for in vitro development of a tendon/ligament tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/term.1589

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 143

Metadata

Authors
Cardwell, R. D., Dahlgren, L. A., & Goldstein, A. S.
Venue
Journal of Tissue Engineering and Regenerative Medicine
Published
2012-10-05
Volume
8
Issue
12
Pages
937-945
ISSN
1932-6254 (ISSN-L)
OpenAlex
W1586736369
Cited by
143
References
5
FWCI
3.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrospun fibre diameter, not alignment, affects mesenchymal stem cell differentiation into the tendon/ligament lineage: Ligament differentiation of C3H10T1/2 cells is enhanced on larger fibres. https://app.cochat.ai/papers/10.1002/term.1589
The paper
Cardwell, R. D., Dahlgren, L. A., & Goldstein, A. S. (2014). Electrospun fibre diameter, not alignment, affects mesenchymal stem cell differentiation into the tendon/ligament lineage: Ligament differentiation of C3H10T1/2 cells is enhanced on larger fibres. Journal of Tissue Engineering and Regenerative Medicine. https://doi.org/10.1002/term.1589

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.