The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hybrid PGS-PCL microfibrous scaffolds with improved mechanical and biological properties
Open accessAbstract
Poly(glycerol sebacate) (PGS) is a biodegradable elastomer that has generated great interest as a scaffold material due to its desirable mechanical properties. However, the use of PGS in tissue engineering is limited by difficulties in casting micro- and nanofibrous structures, due to high temperatures and vacuum required for its curing and limited solubility of the cured polymer. In this paper, we developed microfibrous scaffolds made from blends of PGS and poly(ε-caprolactone) (PCL) using a standard electrospinning set-up. At a given PGS:PCL ratio, higher voltage resulted in significantly smaller fibre diameters (reduced from ∼4 µm to 2.8 µm; p < 0.05). Further increase in voltage resulted in the fusion of fibres. Similarly, higher PGS concentrations in the polymer blend resulted in significantly increased fibre diameter (p < 0.01). We further compared the mechanical properties of electrospun PGS:PCL scaffolds with those made from PCL. Scaffolds with higher PGS concentrations showed higher elastic modulus (EM), ultimate tensile strength (UTS) and ultimate elongation (UE) (p < 0.01) without the need for thermal curing or photocrosslinking. Biological evaluation of these scaffolds showed significantly improved HUVEC attachment and proliferation compared to PCL-only scaffolds (p < 0.05). Thus, we have demonstrated that simple blends of PGS prepolymer with PCL can be used to fabricate microfibrous scaffolds with mechanical properties in the range of a human aortic valve leaflet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314 · cited 6×
“PGS can be easily synthesized from glycerol and sebacic acid, which have been previously approved by the FDA (Wang et al., 2002).”
InfluentialProgress in tissue engineering
Khademhosseini, A., Vacanti, J. P., & Langer, R. (2009) · Scientific American · doi:10.1038/scientificamerican0509-64 · Cited by 403
Self-citation
Cited by
Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review
Rai, R., Tallawi, M., Grigore, A., & Boccaccini, A. R. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.02.001 · Cited by 477
Latest Progress in Electrospun Nanofibers for Wound Healing Applications
Memic, A., Abdullah, T., Mohammed, H. S., Joshi Navare, K., Colombani, T., & Bencherif, S. A. (2019) · ACS Applied Bio Materials · doi:10.1021/acsabm.8b00637 · Cited by 421
Metadata
- Authors
- Sant, S., Hwang, C. M., Lee, S.-H., & Khademhosseini, A.
- Venue
- Journal of Tissue Engineering and Regenerative Medicine
- Publisher
- Hindawi Limited
- Published
- 2011-03-17
- Volume
- 5
- Issue
- 4
- Pages
- 283-291
- ISSN
- 1932-6254 (ISSN-L)
- OpenAlex
- W2002036385
- Cited by
- 162
- References
- 2
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid PGS-PCL microfibrous scaffolds with improved mechanical and biological properties. https://app.cochat.ai/papers/10.1002/term.313
- The paper
- Sant, S., Hwang, C. M., Lee, S.-H., & Khademhosseini, A. (2011). Hybrid PGS-PCL microfibrous scaffolds with improved mechanical and biological properties. Journal of Tissue Engineering and Regenerative Medicine. https://doi.org/10.1002/term.313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.