Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 518

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

A practical and user‐friendly toxicity classification system with microbiotests for natural waters and wastewaters

Persoone, Guido, Marsalek, Blahoslav, Blinova, Irina, Törökne, Andrea, Zarina, Dzidra, Manusadzianas, Levonas, Nalecz‐Jawecki, Grzegorz, Tofan, Lucica, Stepanova, Nadejda, Tothova, Livia, Kolar, Boris · 2003 · Environmental Toxicology

Abstract

Various types of toxicity classification systems have been elaborated by scientists in different countries, with the aim of attributing a hazard score to polluted environments or toxic wastewaters or of ranking them in accordance with increasing levels of toxicity. All these systems are based on batteries of standard acute toxicity tests (several of them including chronic assays as well) and are therefore dependent on the culturing and maintenance of live stocks of test organisms. Most systems require performance of the bioassays on dilution series of the original samples, for subsequent calculation of L(E)C 50 or threshold toxicity values. Given the complexity and costs of these toxicity measurements, they can only be applied in well‐equipped and highly specialized laboratories, and none of the classification methods so far has found general acceptance at the international level. The development of microbiotests that are independent of continuous culturing of live organisms has stimulated international collaboration. Coordinated at Ghent University, Belgium, collaboration by research groups from 10 countries in central and eastern Europe resulted in an alternative toxicity classification system that was easier to apply and substantially more cost effective than any of the earlier methods. This new system was developed and applied in the framework of a cooperation agreement between the Flemish community in Belgium and central and eastern Europe. The toxicity classification system is based on a battery of (culture‐independent) microbiotests and is particularly suited for routine monitoring. It indeed only requires testing on undiluted samples of natural waters or wastewaters discharged into the aquatic environment, except for wastewaters that demonstrate more than 50% effect. The scoring system ranks the waters or wastewaters in 5 classes of increasing hazard/toxicity, with calculation of a weight factor for the concerned hazard/toxicity class. The new classification system was applied during 2000 by the participating laboratories on samples of river water, groundwaters, drinking waters, mine waters, sediment pore waters, industrial effluents, soil leachates, and waste dump leachates and was found to be easy to apply and reliable. © 2003 Wiley Periodicals, Inc. Environ Toxicol 18: 395–402, 2003.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/tox.10141

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 518

Metadata

Authors
Persoone, G., Marsalek, B., Blinova, I., Törökne, A., Zarina, D., Manusadzianas, L., Nalecz‐Jawecki, G., Tofan, L., Stepanova, N., Tothova, L., & Kolar, B.
Venue
Environmental Toxicology
Publisher
Wiley
Published
2003-11-04
Volume
18
Issue
6
Pages
395-402
ISSN
  • 1520-4081 (ISSN-L)
  • 1522-7278
OpenAlex
W2012095919
Cited by
518
References
6
FWCI
3.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.