Objective: Three‐dimensional (3D) transperineal ultrasound has been shown to be a reliable and reproducible method for visualization of morphological changes in the female levator ani muscle. The aim of this study was to evaluate the relationship between persisting pelvic floor disorders 18–24 months after first delivery, biometric measurements of the pelvic floor and mode of delivery. Methods: In this prospective observational study, we recruited on their second day after delivery 130 primiparous women. All were Caucasian and their pregnancies had been singleton with cephalic presentation. 3D transperineal ultrasound was performed, with standardized settings, on the second day (results published previously) and 18–24 months after delivery. Volumes were obtained at rest and on Valsalva maneuver and biometric measurements of the levator hiatus were determined in the axial plane. Obstetric and constitutional parameters were obtained from our clinical files and, 18–24 months after the delivery, a standardized questionnaire was used to evaluate persisting pelvic floor disorders. Ultrasound measurements at 18–24 months were compared according to clinical symptoms of pelvic floor disorders and mode of delivery, including a subgroup analysis of vaginal (spontaneous vs operative vaginal) and Cesarean (primary i.e. elective vs secondary i.e. after onset of labor) delivery groups. Results: Seventy‐seven (59%) women had complete follow‐up at 18–24 months. Biometric measurements showed a significantly larger hiatal area in the vaginal delivery group than in the Cesarean section group 2 years after delivery (P < 0.01), whereas subgroup analysis within the vaginal and Cesarean delivery groups did not show significant differences. Although there was no statistical correlation between delivery mode and persisting stress urinary incontinence, women with persisting stress urinary incontinence 2 years after delivery had a larger hiatal area than did women without this clinical symptom (P < 0.01). There were no significant differences in hiatal dimensions in women with bladder urgency or dyspareunia. Conclusions: 3D transperineal ultrasound, which is easily accessible, can provide useful information on morphological changes of the female pelvic floor. Women with a spontaneous or operative vaginal first delivery had a significantly larger hiatal area and axial distension than did women whose first delivery was by Cesarean section, even 2 years after delivery. Performing 3D ultrasound after the first delivery may help to identify women at high risk for persisting pelvic floor disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.11214

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 39

Metadata

Authors
Falkert, A., Willmann, A., Endress, E., Meint, P., & Seelbach‐Göbel, B.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2013-01-31
Volume
41
Issue
2
Pages
204-209
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1559239073
Cited by
39
References
2
FWCI
1.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.