Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Prediction of pouch of Douglas obliteration in women with suspected endometriosis using a new real-time dynamic transvaginal ultrasound technique: the sliding sign: TVS sliding sign and POD obliteration

Open access
Reid, S., Lu, C., Casikar, I., Reid, G., Abbott, J., Cario, G., Chou, D., Kowalski, D., Cooper, M., Condous, G. · 2013 · Ultrasound in Obstetrics & Gynecology

Abstract

OBJECTIVE: To evaluate preoperative real-time dynamic transvaginal sonography (TVS) in the prediction of pouch of Douglas (POD) obliteration in women undergoing laparoscopy for suspected endometriosis. METHODS: This was a multicenter prospective observational study undertaken from January 2009 to November 2011. All women with symptoms suggestive of endometriosis who were scheduled for laparoscopy underwent detailed preoperative TVS, in particular to ascertain whether the POD was obliterated. POD obliteration was assessed using a real-time TVS technique called the 'sliding sign'. Preoperative TVS sliding sign findings were then compared to gold standard laparoscopic POD findings. RESULTS: One hundred consecutive women with preoperative TVS and laparoscopic outcomes were included in the final analysis. Mean age was 32.8 years and mean age at diagnosis of endometriosis was 27.4 years. At laparoscopy, 84/100 (84%) were found to have some form of endometriosis (73% peritoneal endometriosis, 35% ovarian endometrioma(s), 33% deep infiltrating endometriosis). At laparoscopy, 30/100 (30%) had an obliterated POD and 19/30 (63.3%) of these women also had evidence of bowel endometriosis. The sonographic sliding sign technique had an accuracy of 93.0%, sensitivity of 83.3%, specificity of 97.1%, positive predictive value of 92.6%, negative predictive value of 93.2%, positive likelihood ratio of 29.2 and negative likelihood ratio of 0.17 in the prediction of POD obliteration (P = 1.8E-16). CONCLUSIONS: Preoperative real-time dynamic TVS evaluation using the sliding sign seems to establish with a high degree of certainty whether the POD is obliterated. Given the increased risk of deep infiltrating endometriosis in women with POD obliteration, the TVS sliding sign technique may also be useful in the identification of women who may be at a higher risk for bowel endometriosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.12305

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 176

Metadata

Authors
Reid, S., Lu, C., Casikar, I., Reid, G., Abbott, J., Cario, G., Chou, D., Kowalski, D., Cooper, M., & Condous, G.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2013-05-28
Volume
41
Issue
6
Pages
685-691
ISSN
0960-7692 (ISSN-L)
OpenAlex
W1548845617
Cited by
176
References
2
FWCI
9.16
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.