CoChat

Intraobserver and interobserver reproducibility of fetal biometry

Open access
Perni, S. C., Chervenak, F. A., Kalish, R. B., Magherini‐Rothe, S., Predanic, M., Streltzoff, J., Skupski, D. W. · 2004 · Ultrasound in Obstetrics & Gynecology
Cited by 113

The DOI matches its Crossref record.

Abstract

Objective: To assess the intra‐ and interobserver reproducibility of ultrasound measurements of fetal biometric parameters. Methods: We assessed the intraobserver and the interobserver agreement in measurements of fetal biparietal diameter (BPD), abdominal circumference (AC), head circumference (HC) and femur length (FL) on 122 singleton pregnancies. Patients were each examined twice by the first sonographer to determine the intraobserver reliability of measurements of fetal biometry. Subsequently, during the same ultrasound examination, a second blinded sonographer measured fetal biometric parameters to assess interobserver reliability. The consensus between and among observers was analyzed using the intraclass correlation coefficient (intra‐CC) and interclass correlation coefficient (inter‐CC) and the reliability coefficients (RC, α) for the four biometric measurements. A value > 0.75 was considered a reliable consensus for the intra‐CC and inter‐CC. A Bland and Altman plot was also created for the fetal biometric parameters to assess the repeatability of the measurements. Results: Reliable consensus was observed for both the intra‐CC and inter‐CC and RC for all four biometric parameters. The intra‐CC with the 95% CI and RC for the BPD, AC, HC and FL were as follows: 0.996 (0.995, 0.997), α 0.998; 0.994 (0.992, 0.996), α 0.997; 0.996 (0.994, 0.997), α 0.998; and 0.994 (0.992, 0.996), α 0.997, respectively. Similarly, the inter‐CC with the 95% CI and RC for the same parameters were as follows: 0.995 (0.993, 0.997), α 0.998; 0.980 (0.971, 0.990), α 0.990; 0.994 (0.992, 0.996), α 0.997; and 0.990 (0.985,0.993), α 0.995, respectively. The Bland and Altman plots demonstrated a high degree of repeatability of BPD, AC, HC, and FL measurements. Conclusion: Our results demonstrate that the intra‐ and interobserver reproducibility of ultrasound measurements of fetal biometry are highly reliable. Copyright © 2004 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.1717

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 113

Metadata

Authors
Perni, S. C., Chervenak, F. A., Kalish, R. B., Magherini‐Rothe, S., Predanic, M., Streltzoff, J., & Skupski, D. W.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2004-11
Volume
24
Issue
6
Pages
654-658
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1969362571
Cited by
113
References
0
FWCI
5.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraobserver and interobserver reproducibility of fetal biometry. https://app.cochat.ai/papers/10.1002/uog.1717
The paper
Perni, S. C., Chervenak, F. A., Kalish, R. B., Magherini‐Rothe, S., Predanic, M., Streltzoff, J., & Skupski, D. W. (2004). Intraobserver and interobserver reproducibility of fetal biometry. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.1717

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.