CoChat

Complications of intrauterine intravascular blood transfusion: lessons learned after 1678 procedures

Open access
Zwiers, C., Lindenburg, I. T. M., Klumper, F. J., de Haas, M., Oepkes, D., Van Kamp, I. L. · 2017 · Ultrasound in Obstetrics & Gynecology
Cited by 199

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Objective: Maternal alloimmunization to fetal red‐blood‐cell antigens is a major cause of fetal anemia, which can lead to hydrops and perinatal death if untreated. The cornerstone of management during pregnancy is intrauterine intravascular blood transfusion (IUT). Although this procedure is considered relatively safe, complications continue to occur. The aim of this study was to evaluate rates of procedure‐related complications and perinatal loss following IUT, and their change over time, in order to identify factors leading to improved outcome. Methods: This was a retrospective analysis of all IUTs for red‐cell alloimmunization performed at the national referral center for fetal therapy in The Netherlands, from 1988 to 2015. Differences in complication rates and their associations with alterations in transfusion technique after 2001 were assessed. Results: Between 1988 and 2015, 1678 IUTs were performed in 589 fetuses. For IUTs performed in 2001 and onwards, there was significant improvement in survival (88.6% vs 97.0%, P < 0.001) and a decline in procedure‐related complications per fetus (9.8% vs 3.3%, P = 0.001) and per procedure (3.4% vs 1.2%, P = 0.003) compared with those performed before 2001. Procedure‐related perinatal loss declined from 4.7% to 1.8% per fetus (P = 0.053). Beneficial changes in transfusion technique were routine use of fetal paralysis, increased use of intrahepatic transfusion and avoidance of arterial puncture. Conclusions: IUT has become an increasingly safe procedure in recent years when performed by experienced hands. The chosen technique should be fine‐tuned according to the patient's individual situation. The declining complication rates are most likely related to center volume: this rare procedure is best performed in experienced fetal therapy centers. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.17319

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 199

Metadata

Authors
Zwiers, C., Lindenburg, I. T. M., Klumper, F. J., de Haas, M., Oepkes, D., & Van Kamp, I. L.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2017-08
Volume
50
Issue
2
Pages
180-186
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2528886834
Cited by
199
References
9
FWCI
10.01
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complications of intrauterine intravascular blood transfusion: lessons learned after 1678 procedures. https://app.cochat.ai/papers/10.1002/uog.17319
The paper
Zwiers, C., Lindenburg, I. T. M., Klumper, F. J., de Haas, M., Oepkes, D., & Van Kamp, I. L. (2017). Complications of intrauterine intravascular blood transfusion: lessons learned after 1678 procedures. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.17319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.