CoChat

Consensus definition and essential reporting parameters of selective fetal growth restriction in twin pregnancy: a Delphi procedure

Open access
Khalil, A., Beune, I., Hecher, K., Wynia, K., Ganzevoort, W., Reed, K., Lewi, L., Oepkes, D., Gratacos, E., Thilaganathan, B., Gordijn, S. J. · 2019 · Ultrasound in Obstetrics & Gynecology
Cited by 235

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objectives: Twin pregnancy complicated by selective fetal growth restriction (sFGR) is associated with increased perinatal mortality and morbidity. Inconsistencies in the diagnostic criteria for sFGR employed in existing studies hinder the ability to compare or combine their findings. It is therefore challenging to establish robust evidence‐based management or monitoring pathways for these pregnancies. The main aim of this study was to determine, by expert consensus using a Delphi procedure, the key diagnostic features of and the essential reporting parameters in sFGR. Methods: A Delphi process was conducted among an international panel of experts in sFGR in twin pregnancy. Panel members were provided with a list of literature‐based parameters for diagnosing sFGR and were asked to rate their importance on a five‐point Likert scale. Parameters were described as solitary (sufficient to diagnose sFGR, even if all other parameters are normal) or contributory (those that require other abnormal parameter(s) to be present for the diagnosis of sFGR). Consensus was sought to determine the cut‐off values for accepted parameters, as well as parameters used in the monitoring, management and assessment of outcome of twin pregnancy complicated by sFGR. The questions were presented in two separate categories according to chorionicity. Results: A total of 72 experts were approached, of whom 60 agreed to participate and entered the first round; 48 (80%) completed all four rounds. For the definition of sFGR irrespective of chorionicity, one solitary parameter (estimated fetal weight (EFW) of one twin < 3 rd centile) was agreed. For monochorionic twin pregnancy, at least two out of four contributory parameters (EFW of one twin < 10 th centile, abdominal circumference of one twin < 10 th centile, EFW discordance of ≥ 25%, and umbilical artery pulsatility index of the smaller twin > 95 th centile) were agreed. For sFGR in dichorionic twin pregnancy, at least two out of three contributory parameters (EFW of one twin < 10 th centile, EFW discordance of ≥ 25%, and umbilical artery pulsatility index of the smaller twin > 95 th centile) were agreed. Conclusions: Consensus‐based diagnostic features of sFGR in both monochorionic and dichorionic twin pregnancies, as well as cut‐off values for the parameters involved, were agreed upon by a panel of experts. Future studies are needed to validate these diagnostic features before they can be used in clinical trials of interventions. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.19013

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Khalil, A., Beune, I., Hecher, K., Wynia, K., Ganzevoort, W., Reed, K., Lewi, L., Oepkes, D., Gratacos, E., Thilaganathan, B., & Gordijn, S. J.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2019-01
Volume
53
Issue
1
Pages
47-54
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2787326263
Cited by
235
References
6
FWCI
17.13
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.