CoChat

Maternal kidney function during pregnancy: systematic review and meta‐analysis

Open access
Lopes van Balen, V. A., van Gansewinkel, T. A. G., de Haas, S., Spaan, J. J., Ghossein‐Doha, C., van Kuijk, S. M. J., van Drongelen, J., Cornelis, T., Spaanderman, M. E. A. · 2019 · Ultrasound in Obstetrics & Gynecology
Cited by 129

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives: To review systematically current literature on kidney function changes during pregnancy, in order to estimate the extent of adaptation over the course of both healthy physiological and complicated singleton pregnancies, and to determine healthy pregnancy reference values. Methods: PubMed (NCBI) and EMBASE (Ovid) electronic databases were searched, from inception to July 2017, for studies on kidney function during uncomplicated and complicated pregnancies. Included studies were required to report a non‐pregnant reference value of kidney function (either in a non‐pregnant control group or as a prepregnancy or postpartum measurement) and a pregnancy measurement at a predetermined and reported gestational age. Kidney function measures assessed were glomerular filtration rate (GFR) measured by inulin clearance, GFR measured by creatinine clearance and serum creatinine level. Pooled mean differences between pregnancy measurements and reference values were calculated for predefined intervals of gestational age in uncomplicated and complicated pregnancies using a random‐effects model described by DerSimonian and Laird. Results: Twenty‐nine studies met the inclusion criteria and were included in the analysis. As early as the first trimester, GFR was increased by up to 40–50% in physiological pregnancy when compared with non‐pregnant values. Inulin clearance in uncomplicated pregnancy was highest at 36–41 weeks, with a 55.6% (53.7; 95% CI, 44.7–62.6 mL/min) increase when compared with non‐pregnant values, and creatinine clearance was highest at 15–21 weeks' gestation, with a 37.6% (36.6; 95% CI, 26.2–46.9 mL/min) increase. Decrease in serum creatinine level in uncomplicated pregnancy was most prominent at 15–21 weeks, with a 23.2% (−0.19; 95% CI, −0.23 to −0.15 mg/dL) decrease when compared with non‐pregnant values. Eight studies reported on pregnancies complicated by a hypertensive disorder. Meta‐regression analysis showed a significant difference in all kidney function parameters when comparing uncomplicated and hypertensive complicated pregnancies. Conclusions: In healthy pregnancy, GFR is increased as early as the first trimester, as compared with non‐pregnant values, and the kidneys continue to function at a higher rate throughout gestation. In contrast, kidney function is decreased in hypertensive pregnancy. © 2018 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.20137

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 129

Metadata

Authors
Lopes van Balen, V. A., van Gansewinkel, T. A. G., de Haas, S., Spaan, J. J., Ghossein‐Doha, C., van Kuijk, S. M. J., van Drongelen, J., Cornelis, T., & Spaanderman, M. E. A.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2019-08-06
Volume
54
Issue
3
Pages
297-307
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2895299813
Cited by
129
References
3
FWCI
1.83
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.