Cited by 29Prenatal Screening and DiagnosticsUltrasound in Clinical ApplicationsPregnancy and preeclampsia studies

Expected‐value bias in routine third‐trimester growth scans

Open access
Drukker, L., Droste, R., Chatelain, P., Noble, J. A., Papageorghiou, A. T.·2020·Ultrasound in Obstetrics & Gynecology

Abstract

Objectives: Operators performing fetal growth scans are usually aware of the gestational age of the pregnancy, which may lead to expected‐value bias when performing biometric measurements. We aimed to evaluate the incidence of expected‐value bias in routine fetal growth scans and assess its impact on standard biometric measurements. Methods: We collected prospectively full‐length video recordings of routine ultrasound growth scans coupled with operator eye tracking. Expected value was defined as the gestational age at the time of the scan, based on the estimated due date that was established at the dating scan. Expected‐value bias was defined as occurring when the operator looked at the measurement box on the screen during the process of caliper adjustment before saving a measurement. We studied the three standard biometric planes on which measurements of head circumference (HC), abdominal circumference (AC) and femur length (FL) are obtained. We evaluated the incidence of expected‐value bias and quantified the impact of biased measurements. Results: We analyzed 272 third‐trimester growth scans, performed by 16 operators, during which a total of 1409 measurements (354 HC, 703 AC and 352 FL; including repeat measurements) were obtained. Expected‐value bias occurred in 91.4% of the saved standard biometric plane measurements (85.0% for HC, 92.9% for AC and 94.9% for FL). The operators were more likely to adjust the measurements towards the expected value than away from it (47.7% vs 19.7% of measurements; P < 0.001). On average, measurements were corrected by 2.3 ± 5.6, 2.4 ± 10.4 and 3.2 ± 10.4 days of gestation towards the expected gestational age for the HC, AC, and FL measurements, respectively. Additionally, we noted a statistically significant reduction in measurement variance once the operator was biased (P = 0.026). Comparing the lowest and highest possible estimated fetal weight (using the smallest and largest biased HC, AC and FL measurements), we noted that the discordance, in percentage terms, was 10.1% ± 6.5%, and that in 17% (95% CI, 12–21%) of the scans, the fetus could be considered as small‐for‐gestational age or appropriate‐for‐gestational age if using the smallest or largest possible measurements, respectively. Similarly, in 13% (95% CI, 9–16%) of scans, the fetus could be considered as large‐for‐gestational age or appropriate‐for‐gestational age if using the largest or smallest possible measurements, respectively. Conclusions: During routine third‐trimester growth scans, expected‐value bias frequently occurs and significantly changes standard biometric measurements obtained. © 2019 the Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.21929

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • As operators seem to be at risk of expected-value bias when acquiring fetal biometry measurements, an algorithm training to measure standard biometric planes by supervised learning might end up having a built-in bias when automatically calculating fetal biometry.

    “For example, as operators seem to be at risk of expected‐value bias when acquiring fetal biometry measurements, an algorithm training to measure standard biometric planes by supervised learning might end up having a built‐in bias when automatically calculating fetal biometry 59 .”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 28 · Cited by 29

Authors
Drukker, L., Droste, R., Chatelain, P., Noble, J. A., & Papageorghiou, A. T.
Affiliations
University of Oxford (GB)
Corresponding author
Papageorghiou, A. T.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2020-03
Volume
55
Issue
3
Pages
375-382
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2990133788
Cited by
29
References
28
Citations by year
2026: 2 · 2025: 4 · 2024: 4 · 2023: 2 · 2022: 5 · 2021: 7 · 2020: 5
FWCI
4.42
Type
journal article
Language
en
Open access
Locations
  • Ultrasound in Obstetrics and Gynecology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • St George's Online Research Archive (St George's University of London) (acceptedVersion)
Funders
H2020 European Research Council (ERC‐ADG‐2015 694581)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
Keywords
third trimester, gestational age, fetal biometry, head circumference, abdominal circumference, femur length, measurement bias, measurement variance, estimated fetal weight, small for gestational age, appropriate for gestational age, ultrasound measurement accuracy
MeSH terms
Abdomen, Biometry, Female, Femur, Fetus, Gestational Age, Head, Humans, Pregnancy, Pregnancy Trimester, Third, Prospective Studies, Reference Values, Video Recording, Observer Variation, Ultrasonography, Prenatal, Fetal Development

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review