Abstract

Objective: To examine in monochorionic pregnancies the possible value of intertwin discordance in nuchal translucency (NT) thickness in the prediction of early fetal death or severe twin–twin transfusion syndrome (TTTS). Methods: In 512 monochorionic twin pregnancies NT was measured at 11 to 13 + 6 weeks' gestation and regression analysis was used to determine the significance of the association between the intertwin discordance in NT and subsequent early fetal death or development of severe TTTS requiring endoscopic laser surgery. Results: In 412 (80.5%) pregnancies there was a normal outcome, in 58 (11.3%) there was severe TTTS requiring endoscopic laser surgery at 18–24 weeks, in 19 (3.7%) there was death of one or both fetuses at 13–18 weeks and in 23 (4.5%) there was fetal death at 21–38 weeks. In the four outcome groups the median discordance in NT was 11%, 22%, 35% and 7%, respectively. Significant prediction of early fetal death and severe TTTS was provided by the discordance in fetal NT, which was not significantly improved by including the discordance in crown–rump length. If the discordance in NT was 20% or more, the false positive rate was 20%, the detection rate of early fetal death was 63% and the detection rate of severe TTTS was 52%. Conclusions: Discordance in NT of 20% or more is found in about 25% of monochorionic twins and in this group the risk of early fetal death or development of severe TTTS is more than 30%. If the discordance is less than 20% the risk of complications is less than 10%. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.4006

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 185

Metadata

Authors
Kagan, K. O., Gazzoni, A., Sepulveda‐Gonzalez, G., Sotiriadis, A., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2007-04-20
Volume
29
Issue
5
Pages
527-532
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2126173906
Cited by
185
References
11
FWCI
11.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Discordance in nuchal translucency thickness in the prediction of severe twin‐to‐twin transfusion syndrome. https://app.cochat.ai/papers/10.1002/uog.4006
The paper
Kagan, K. O., Gazzoni, A., Sepulveda‐Gonzalez, G., Sotiriadis, A., & Nicolaides, K. H. (2007). Discordance in nuchal translucency thickness in the prediction of severe twin‐to‐twin transfusion syndrome. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.4006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.