Computer‐aided diagnosis using morphological features for classifying breast lesions on ultrasound
The DOI matches its Crossref record.
Abstract
Objectives: To develop and evaluate a computer‐aided diagnosis (CAD) system with automatic contouring and morphological analysis to aid in the classification of breast tumors using ultrasound. Methods: We evaluated 118 breast lesions (34 malignant and 84 benign tumors). Each tumor contour was automatically extracted from the digitized ultrasound image. Nineteen practical morphological features from the extracted contour were calculated and principal component analysis (PCA) was applied to find independent features. A support vector machine (SVM) classifier utilized the selected principal vectors to identify the breast tumor as benign or malignant. In this study, all the cases were sampled with k‐fold cross‐validation (k = 10) to evaluate the performance by receiver–operating characteristics (ROC) curve analysis. Results: The areas under the ROC curves for the proposed CAD systems using all morphological features and the lower‐dimensional principal vector were 0.91 and 0.90, respectively. The classification ability for breast tumors using morphological information was good. Conclusions: This system differentiates benign from malignant breast tumors well and therefore provides a clinically useful second opinion. Moreover, the morphological features are nearly setting‐independent and thus available to various ultrasound machines. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cheng, J.-Z., Ni, D., Chou, Y.-H., Qin, J., Tiu, C.-M., Chang, Y.-C., Huang, C.-S., Shen, D., & Chen, C.-M. (2016) · Scientific Reports · doi:10.1038/srep24454 · Cited by 755
Moon, W. K., Lee, Y.-W., Ke, H.-H., Lee, S. H., Huang, C.-S., & Chang, R.-F. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105361 · Cited by 318
Self-citationIntroduction to artificial intelligence in ultrasound imaging in obstetrics and gynecology
Drukker, L., Noble, J. A., & Papageorghiou, A. T. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22122 · Cited by 240
“…to evaluate adnexal masses 21 , the risk of lymph node metastases in endometrial cancer 22 , pelvic organ function 23,24 and breast lesions 25–27 , assess aneuploidy risk 28 , predict fetal lung maturity 29 , perinatal outcome 30 , shoulder dystocia 31 and brain damage 32 , estimate…”
BackgroundDhombres, F., Bonnard, J., Bailly, K., Maurice, P., Papageorghiou, A. T., & Jouannic, J.-M. (2022) · Journal of Medical Internet Research · doi:10.2196/35465 · Cited by 93
Metadata
- Authors
- Huang, Y. ‐., Chen, D. ‐., Jiang, Y. ‐., Kuo, S. ‐., Wu, H. ‐., & Moon, W. K.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2008-03-31
- Volume
- 32
- Issue
- 4
- Pages
- 565-572
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2084985476
- Cited by
- 106
- References
- 0
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer‐aided diagnosis using morphological features for classifying breast lesions on ultrasound. https://app.cochat.ai/papers/10.1002/uog.5205
- The paper
- Huang, Y. ‐., Chen, D. ‐., Jiang, Y. ‐., Kuo, S. ‐., Wu, H. ‐., & Moon, W. K. (2008). Computer‐aided diagnosis using morphological features for classifying breast lesions on ultrasound. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.5205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.