Ovarian volume and follicle number in the diagnosis of polycystic ovary syndrome in Chinese women
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective: To assess the value of ovarian volume and follicle number in the diagnosis of polycystic ovary syndrome (PCOS) in a Chinese population. Methods: This study included 432 women with PCOS selected using the National Institutes of Health criteria, who were compared with 153 age‐matched women as controls. All participants were given a transvaginal or transrectal ultrasound scan during day 3–5 of the menstrual cycle (for regularly menstruating women) or randomly (for oligomenorrheic or amenorrheic women). The ovarian volume (calculated using the simplified formula: 0.5 × length × height × width) and follicle number were obtained and the best diagnostic cut‐off values were evaluated using receiver–operating characteristics (ROC)‐curve analysis. Results: The 10th and 90th centiles of ovarian volume in PCOS patients were 4.89 and 15.79 cm 3, respectively, and the median was 9.21 cm 3; the 10th and 90th centiles of follicle number were 8 and 19, respectively, and the median was 12. The 10th and 90th centiles of ovarian volume in controls were 2.43 and 7.75 cm 3, respectively, and the median was 4.46 cm 3; the 10th and 90th centiles of follicle number were 3 and 10, respectively, and the median was 6. The differences in ovarian volume and follicle number between patients and controls were statistically significant. The areas under the ROC curves for mean ovarian volume (MOV), maximum ovarian volume (MaxOV), mean follicle number (MFN) and maximum follicle number (MaxFN) to diagnose PCOS were 0.898, 0.882, 0.909 and 0.911, respectively. Setting the threshold for MOV at 6.4 cm 3 (sensitivity 81%, specificity 85.6%), the threshold for MaxOV at 7.9 cm 3 (sensitivity 78%, specificity 85.6%), the threshold for MFN at 10 (sensitivity 85.2%, specificity 88.8%) and the threshold for MaxFN at 12 (sensitivity 85.2%, specificity 92.6%) obtained the best compromise between sensitivity and specificity, based on the Youden index. Conclusions: We conclude that ovarian volume and follicle number have satisfactory power for use in the diagnosis of PCOS. Cut‐offs of 6.4 cm 3, 7.9 cm 3, 10 and 12, for MOV, MaxOV, MFN and MaxFN, respectively, obtained the best compromise between sensitivity and specificity for the diagnosis of PCOS in Chinese women. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasound assessment of the polycystic ovary: international consensus definitions
Balen, A. H., Laven, J. S. E., Tan, S.-L., & Dewailly, D. (2003) · Human Reproduction Update · doi:10.1093/humupd/dmg044 · Cited by 1,015
Cited by
Goodman, N. F., Cobin, R. H., Futterweit, W., Glueck, J. S., Legro, R. S., & Carmina, E. (2015) · Endocrine Practice · doi:10.4158/ep15748.dsc · Cited by 623
Dewailly, D., Lujan, M. E., Carmina, E., Cedars, M. I., Laven, J., Norman, R. J., & Escobar-Morreale, H. F. (2014) · Human Reproduction Update · doi:10.1093/humupd/dmt061 · Cited by 551
Lujan, M. E., Jarrett, B. Y., Brooks, E. D., Reines, J. K., Peppin, A. K., Muhn, N., Haider, E., Pierson, R. A., & Chizen, D. R. (2013) · Human Reproduction · doi:10.1093/humrep/det062 · Cited by 459
Current Guidelines for Diagnosing PCOS
Christ, J. P., & Cedars, M. I. (2023) · Diagnostics · doi:10.3390/diagnostics13061113 · Cited by 340
Metadata
- Authors
- Chen, Y., Li, L., Chen, X., Zhang, Q., Wang, W., Li, Y., & Yang, D.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2008-09-04
- Volume
- 32
- Issue
- 5
- Pages
- 700-703
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2003653707
- Cited by
- 60
- References
- 1
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.