CoChat

Effect of a low‐lying placenta on delivery outcome

Open access
Bronsteen, R., Valice, R., Lee, W., Blackwell, S., Balasubramaniam, M., Comstock, C. · 2009 · Ultrasound in Obstetrics & Gynecology
Cited by 54

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objectives: To evaluate delivery outcome in pregnancies with a low‐lying placenta (within 2 cm of, but not covering, the internal os) that had been identified within 4 weeks of delivery. We examined the likelihood of a vaginal delivery and investigated the clinical significance of the placental edge to internal os measurement. Methods: A retrospective chart review was performed for singleton pregnancies delivering in the third trimester with a low‐lying placenta identified within 4 weeks of delivery. Outcome variables included type of delivery, maternal and neonatal hemoglobin levels, and umbilical artery pH levels. Results: Eighty‐six patients met the study criteria of a low‐lying placenta identified within 4 weeks of delivery. Forty‐five of these patients were allowed to labor and, of these, 29 (64.4%) delivered vaginally. The vaginal delivery rate was 76.5% in patients with a placenta to cervical os distance of 1–2 cm, significantly greater than the rate of 27.3% in patients in whom the placenta was within 1 cm of the cervix (P = 0.0085). A maternal hemoglobin level below 8.0 g/dL was the most common morbidity associated with low‐lying placenta. Analysis of morbidity observed did not clearly favor either elective Cesarean delivery or attempted vaginal delivery. Conclusions: In this retrospective study, most laboring patients with a low‐lying placenta were able to have a vaginal delivery with limited morbidity. The likelihood of a vaginal delivery was greater with increased placenta to cervical os distance. Further studies are needed to determine the clinical significance of the placenta to cervical os distance and the interval from scan to delivery. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.6304

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 54

Metadata

Authors
Bronsteen, R., Valice, R., Lee, W., Blackwell, S., Balasubramaniam, M., & Comstock, C.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2009-01-27
Volume
33
Issue
2
Pages
204-208
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2088793624
Cited by
54
References
2
FWCI
3.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of a low‐lying placenta on delivery outcome. https://app.cochat.ai/papers/10.1002/uog.6304
The paper
Bronsteen, R., Valice, R., Lee, W., Blackwell, S., Balasubramaniam, M., & Comstock, C. (2009). Effect of a low‐lying placenta on delivery outcome. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.6304

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.